01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Body, rear32 Bonnet, flaps, cab, central locking33 Front door, central locking34 Rear door, sliding door, wing doors, central locking35 Sliding roof36 Bumper37 Glazing/window mechanism38 Exterior equipment39 Interior equipment40 Passenger protection41 Trim, noise insulation42 Seat padding, covers43 Heating44 Aux. heater/heater booster45 Air conditioner46 Instruments, GCI47 Infotainment48 Windscreen wipe/wash system49 Lights, lamps, switches outside50 Lights, lamps, switches inside, anti-theft system51 Wiring
SEAT Alhambra (1996-2010)01 · Technical data
01 · General

Specifications:

Make
SEAT
Model
Alhambra
Year
1996–2010
Section
Air conditioning system with refrigerant R134a › Specifications:
Technical dataSpecifications:

Specifications:

Heating, ventilation, air conditioning system · Air conditioning system with refrigerant R134a · Checking pressures on vehicles · Alhambra from 1996 · Edition 02.2006

High-pressure side:

From initial pressure (upon connecting the manometer) increasing to a maximum of 20 bar positive pressure.

Low-pressure side:

From initial pressure (upon connecting the manometer) decreasing to the diagram value.

A87-0146
A High pressure in bar positive pressure.B Low pressure in bar positive pressure.C Permitted tolerance range.
Possible deviation from specificationPossible cause of faultRectifying fault
High pressure remains constant or increases only slightly (above the pressure measured when the engine is stopped),Low pressure falls quickly to the diagram value or lower, the required cooling power is not delivered.Too little refrigerant in circuit or expansion valve defective.Extract some refrigerant from the refrigerant circuit.The quantity of refrigerant extracted is about equal to the prescribed charge quantity.Renew expansion valve.Recharge refrigerant circuit.Repeat check.
High pressure normal,Low pressure matches the diagram value,the required cooling power is not delivered.The quantity of refrigerant extracted is significantly less than the prescribed charge quantity.Look for leaks using leak detector and rectify them.Recharge refrigerant circuit.Repeat check.

Note!

  • If no fault can be determined and the function of the air conditioning system is not OK when the test is repeated, flush refrigerant circuit with compressed air and nitrogen.
Possible deviation from specificationPossible cause of faultRectifying fault
High pressure increases beyond the specification,Low pressure falls quickly to the diagram value or lower, the required cooling power is not delivered.Restriction or obstruction in the refrigerant circuit.Expansion valve defective.Feel the refrigerant circuit with the hand to sense the temperature gradient.At one component a temperature gradient will be detected:If a hose or pipe is kinked or crushed, renew it.In case of an obstruction, flush refrigerant circuit with compressed air and nitrogen and renew expansion valve.If no faults are found:Rinse (clean) refrigerant circuit Chapter “Rinsing (cleaning) refrigerant circuit with refrigerant R134a”.Repeat check.

Note!

  • If the air conditioning system is still not operating correctly after the refrigerant circuit has been purged with compressed air and nitrogen, the expansion valve must be renewed.
Possible deviation from specification Possible cause of faultRectifying fault
High pressure and low pressure are normal at first, after a while, the high pressure increases beyond the specification, and the low pressure falls to the diagram value or lower,the cooling power called for is not delivered.Expansion valve defective.Moisture in the refrigerant circuit.Examine the expansion valve for dirt or corrosion; renew if necessary.Flush refrigerant circuit with compressed air and nitrogen.Renew receiver.Repeat the check; if the system does not operate correctly Rinse (clean) refrigerant circuit Chapter “Rinsing (cleaning) refrigerant circuit with refrigerant R134a”.Recharge refrigerant circuit.Repeat check.

Note!

  • When this fault occurs, always renew receiver.
Possible deviation from specification Possible cause of faultRectifying fault
High pressure normal or too high (see diagram), the required cooling power is not delivered.The air conditioner compressor is noisy (especially immediately after being switched on),Too much refrigerant in circuit.Expansion valve or air conditioner compressor defective.Extract some refrigerant from the refrigerant circuit.The quantity of refrigerant extracted is about equal to the prescribed charge quantity.Renew expansion valve.Recharge refrigerant circuit.Repeat test.The quantity of refrigerant extracted is significantly greater than the prescribed charge quantity.Recharge refrigerant circuit.Repeat check.

Note!

  • If the air conditioning system is still not operating correctly when the test is repeated, refit the expansion valve and flush the refrigerant circuit with compressed air and nitrogen. Then renew the air conditioner compressor and receiver.
Possible deviation from specificationPossible cause of faultRectifying fault
High pressure increases only slightly above the pressure measured when the engine is stopped,Low pressure falls only slightly, the required cooling power is not delivered.The air conditioner compressor is defective.Rinse (clean) refrigerant circuit Chapter “Rinsing (cleaning) refrigerant circuit with refrigerant R134a”.Renew the air conditioner compressor and receiver.
Possible deviation from specificationPossible cause of faultRectifying fault
High pressure normal,Low pressure is too low (see diagram),the cooling power called for is delivered.Expansion valve or air conditioner compressor defective.Renew expansion valve.Recharge refrigerant circuit.Repeat check.

Note!

Possible deviation from specification Possible cause of faultRectifying fault
High pressure and low pressure are normal, the required cooling power is not delivered.Too much refrigerant in the circuit.Evacuate refrigerant circuit.Rinse (clean) refrigerant circuit Chapter “Rinsing (cleaning) refrigerant circuit with refrigerant R134a”.
High pressure and low pressure are normal,The air conditioner compressor is noisy (especially immediately after being switched on),the cooling power called for is delivered.

Note!

  • Overfilling with refrigerant oil can occur if the refrigerant oil level was not checked after the air conditioner compressor was renewed.