Statutes and regulations
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Air conditioning system with refrigerant R134a › Statutes and regulations
Statutes and regulations
Note!
- The laws and regulations listed below are valid in the Federal Republic of Germany. Other or additional laws and regulations may apply in other countries.
- Sources in other countries may be obtained from the responsible authorities.
(1) It is forbidden, during operation, maintenance and decommissioning of products that contain refrigerant as defined in § 3, contrary to the state of technology, to allow the substances contained to escape into the atmosphere.
Records must be kept regarding quantities used in operation and in maintenance work (operating log for refrigerants; see SEAT After Sales; ServiceNet; SEAT ServiceNet; handbooks; SOH; Environment; Volume 2; Emissions protection; Refrigerant from air conditioning systems and refrigerant oils) and presented to the appropriate authorities on request.
(2) Companies which sell materials and preparations listed under § 1 sections 1 and 2 have the duty of accept returned materials and preparations after they have been used, or to ensure that a specified third party will accept them.
(3) Repair work and decommissioning of products that contain refrigerant in accordance with § 3, together with acceptance of returned materials and preparations listed under § 1 sections 1 and 2 may be performed only be persons who have the necessary technical knowledge and equipment necessary for this.
(3) It is an offence under § 26 section 1 no. 7 of the Chemicals Act deliberately or negligently in breach of § 8 section 1 para 1 during operation, maintenance and decommissioning of products that contain refrigerant as defined in § 3, contrary to the state of technology, to allow the substances contained to escape into the atmosphere or deliberately or negligently fails to comply with the duty under § 8 section 1 para 2 to keep records.
The following paragraphs are only extracts relevant to vehicle manufacturers and workshops.
2. Specification of terms and explanations
2. 1 Charging systems
2.1.1 Charging systems are systems for charging locally mobile pressurised gas containers. The charging system's operational facilities and furnishings are part of the charging system.
2. 4 Charging systems requiring permits
Charging systems that require authorisation are charging systems which are filled with pressurised gases in mobile gas pressure vessels for transfer to other vessels.
5 Charging systems that do not require a permit are mobile charging systems in which pressurised gases are transferred to gas pressure vessels for exclusive use of one company.
This does not apply to vehicle manufacturers and workshops.
2. Employees and their instruction
2. 1 Charging systems may be operated and maintained only by persons who
- are at least 18 years of age
- possess the required technical knowledge
- can be expected to fulfil their duties reliably.
2. 2 Supervised work may be done by persons who do not fulfil the requirements according to Number 2, lines 1 and 2.
2. 3 Employees are to be instructed in the following points before beginning work and at regular, appropriate intervals, but at least annually:
- the particular hazards arising when handling gases under pressure,
- the safety regulations, particularly the existing TRG,
- the actions to be taken in the event of defects, damage and accidents,
- the handing of fire extinguishers and protective equipment,
- the operation and maintenance of charging systems, with particular reference to the user's manual.
A gas pressure vessel may be charged only with the compressed gas that is listed on its label, and only up to the quantity shown on the vessel in terms of pressure, weight and volume (see g15 section 2 of the pressure vessel regulations).
2. A container that optionally can be used for more than one compressed gas must have the pressurised gases with which it may be charged listed on the container label, and if the compressed gas concerned has tc ≥ -10° C (tc = critical temperature), also the greatest permissible charging weight in accordance with TRG 104 no. 3 before being connected for charging.
3. Gas pressure vessels for which the highest permissible charge positive pressure at 15° C is given in bar must be charged by pressure manometer. If during charging the temperature differs from 15° C, the pressure corresponding to the different temperature should be determined by the charging equipment; it must be ensured that the permissible positive pressure for charging at 15° C in the gas pressure vessel is not exceeded. To determine possible overcharging, the charged containers must be checked through random pressure tests.
4. Pressurised containers on which the maximum permissible charging quantity is indicated by the net weight (charged weight, permissible weight of the contents) in kilograms must be charged according to weight (gravimetrically). The containers must be weighed during charging and, to determine possible overcharging subsequently subjected to a weight check on a special scale. Scales for control weighing must be calibrated.
5. Under particular conditions, gases with tc ≥ +70° C from gas pressure vessels of no more than 150l volumetric contents may be charged into a gas pressure vessel of no more than 1000 ccm volumetric contents. The conditions of the TRG apply to charging mechanic's bottles with liquid gas.
6. Vehicle container for
(1) gases with tc ≥ +70° C (see TRG 101 appendix 3)
(2) technical gas mixtures with tc ≥ +70° C (see TRG 102 appendix 1 group 3) or
(3) very cold liquid gases (see TRG 103) in variance to no. 4 may be charged by volume (volumetrically), if the charging device and/or the container with equipment is equipped with devices for measuring or limiting the volume of the charge and (except vehicle containers to no. 3) for measuring the temperature of the charge. When charging by volume, ensure that the permitted charge weight shown on the container is not exceeded. To determine possible overcharging, the charged containers are to be checked gravimetrically on a calibrated scale or – provided that the pressurised gases are not highly toxic – volumetrically. Volumetric checking presupposes that the appropriate equipment is in place; charging and checking equipment must be independent of each other.
7. The charge and check measurements must not be performed by the same person. Check measurements must be performed immediately upon conclusion of the charging process.
8. Overcharged containers must be discharged immediately to the permissible charge quantity and in a manner without hazard. Following this, the quantity of compressed gas charged must be determined once again.
9. Numbers 4 through 7 do not apply to containers for deep-cooled liquid pressurised gases which are neither flammable nor toxic; regulations for traffic law remain unaffected.
10. When gas pressure vessels are to be charged with gases in the liquid state at charging temperatures ≤ -20° C, the gas pressure vessel (if the vessel material is not tested for temperatures ≤ -20° C) must be released from the charging system for transportation only when the vessel wall has achieved a temperature ≥ +20° C.
Note!
- Due to the environmental situation and the ensuing legislation, refrigerant R12 is currently neither in production nor available. Refrigerant R134a was developed as a replacement for R12.
- However, air conditioning systems developed and designed for refrigerant R12 cannot simply be charged with refrigerant R134a. To ensure trouble-free operation of the air conditioning system following a retrofit, various components of the refrigerant circuit must be replaced.
- Repair manual for air conditioning systems with refrigerant R12 parts 2 and 3. This workshop manual is only available as a hard copy.
According to environmental statistics law, it is required to keep records concerning the use of refrigerants.
Car manufacture and repair businesses must be prepared to furnish information concerning use of refrigerants to the statistical office for the country in which the work is being performed. It is therefore recommended to keep records regarding quantities used in operation and in maintenance work (operating log for refrigerants), see SEAT After Sales; ServiceNet; SEAT ServiceNet; handbooks; SOH; Environment; Volume 2; Emissions protection; Refrigerant from air conditioning systems and refrigerant oils) and presented to the appropriate authorities on request.