Renewing components
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Air conditioning system with refrigerant R134a › Renewing components
‹ Prev Specifications:Next › In the event of leaking or damaged components (apart from the air conditioner compressor, receiver or reservoir)
Technical dataRenewing components
Renewing components
- All components of the refrigerant circuit submitted for quality monitoring must always be sealed (use the original sealing caps from the genuine part).
- The genuine parts (A/C compressor, reservoir, receiver, evaporator and condenser) are charged with nitrogen before shipment. This charge gradually escapes, or the pressure of the nitrogen is low, so that when the seals are opened, escaping gas is not noticeable.
- Chapter “Basics for working on refrigerant circuit”.
- A/C compressor regulating valve, air conditioning system N280 (without magnetic clutch) has an internal oil circuit to ensure that the A/C compressor is not damaged when the refrigerant circuit is empty. This means that about 40 to 50 cm3 refrigerant oil remains in the A/C compressor Chapter “Basics for working on refrigerant circuit”.
Note!
- Since genuine parts are sometimes stored for long periods in various places, it can well be that gas will escape from some parts when first opened but not from others (even among those having the same part number). Therefore, be careful when unscrewing the sealing plugs from the genuine part connections and allow the nitrogen gas to escape slowly.
- Either a restrictor with a reservoir or an expansion valve with a receiver are built into the refrigerant circuit.
- Seal open connections and lines to prevent moisture from entering.
- Always renew restrictor.
- The reservoir or receiver or cartridge of the dryer bag need not be renewed under the following circumstances:
- After an accident in which there was no damage to the reservoir or receiver.
- Repairs are performed quickly (no more delay than during a normal repair time) and there was no moisture intrusion. The vehicle is no more than 5 years old.
- The reservoir or receiver or dryer cartridge should be renewed under the following circumstances:
- The refrigerant circuit was opened and the vehicle is more than 5 years old.
- The refrigerant circuit has been opened for in indeterminate period (seepage leak).
- Repairs take longer than a normal repair time and there has been moisture intrusion.
- The reservoir or receiver or dryer cartridge should always be renewed after the refrigerant circuit has been flushed. During this work, keep the components sealed for as long as possible, to minimise the absorption of moisture.
- The air conditioner compressor seizes.
- The reservoir or receiver is damaged (e.g. in an accident).
Warning
- For instructions on handling refrigerant oil see SEAT After Sales; ServiceNet; SEAT ServiceNet; handbooks; SOH; Environment; Volume 2, Emissions protection; Refrigerant from air conditioning systems / refrigerant oils.
‹ Prev Specifications:Next › In the event of leaking or damaged components (apart from the air conditioner compressor, receiver or reservoir)
Parts & tools for this job For 1996 SEAT Alhambra
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Alhambra 1996 cabin filter
As an Amazon Associate we earn from qualifying purchases.