Workshop Manuals Factory service & repair SEAT
01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Body, rear32 Bonnet, flaps, cab, central locking33 Front door, central locking34 Rear door, sliding door, wing doors, central locking35 Sliding roof36 Bumper37 Glazing/window mechanism38 Exterior equipment39 Interior equipment40 Passenger protection41 Trim, noise insulation42 Seat frames43 Seat padding, covers44 Heating45 Air conditioner46 Infotainment47 Windscreen wipe/wash system48 Lights, lamps, switches outside49 Lights, lamps, switches inside, anti-theft system50 Wiring
SEAT Toledo (1M, 1999-2004)45 · Air conditioner
45 · Heating & A/C

Condenser: removing and installing

Make
SEAT
Model
Toledo
Year
1M, 1999–2004
Section
Heating, ventilation and air conditioning › Condenser: removing and installing
Air conditionerCondenser: removing and installing

Condenser: removing and installing

Heating, ventilation, air conditioning system · Heating, ventilation and air conditioning · Refrigeration agent circuit: repairs · Toledo / León from 1999 · Edition 10.2006

Empty the refrigerant circuit Air conditioning with refrigerant R134a.

Warning

There is a freezing hazard.

If any trace of refrigerant is left in the circuit

Extract all the refrigerant before opening the circuit.

Unscrew the bolt (A) (tightening torque: 15 Nm).

A87-0130

Remove refrigerant hoses (B).

Unscrew hexagon nut (C).

Unscrew the bolt (D) (tightening torque: 15 Nm).

Remove the condenser (G) from casing, pulling it downwards.

Note

  • (E) and (F) (10.8 mm; 1.8 mm).
  • Keep the liquid tank closed as much as possible; remove the caps immediately before assembly (There is a bag of drying agent in the condenser. This becomes soaked very quickly if the tank is left open and is rendered useless)
  • Air conditioning with refrigerant R134a
  • Inside the condenser that has been removed, there is refrigeration oil that must be added to the refrigeration circuit (with the new condenser).
  • The quantity of oil is adjusted depending on the fault. If, for example, only the condenser has been damaged (no refrigerant has been lost and no damp or dirt has entered the refrigerant circuit), the air conditioning can be easily repaired by weighing the old and the new condensers (the new condenser should be topped up with refrigerant oil until it reaches the weight of the old condenser).

Parts & tools for this job For 1999 SEAT Toledo