Condenser: removing and installing
- Make
- SEAT
- Model
- Toledo
- Year
- 1M, 1999–2004
- Section
- Heating, ventilation and air conditioning › Condenser: removing and installing
Air conditionerCondenser: removing and installing
Condenser: removing and installing
Empty the refrigerant circuit Air conditioning with refrigerant R134a.
Warning
There is a freezing hazard.
If any trace of refrigerant is left in the circuit
Extract all the refrigerant before opening the circuit.
Unscrew the bolt (A) (tightening torque: 15 Nm).

Remove refrigerant hoses (B).
Unscrew hexagon nut (C).
Unscrew the bolt (D) (tightening torque: 15 Nm).
Remove the condenser (G) from casing, pulling it downwards.
Note
- (E) and (F) (10.8 mm; 1.8 mm).
- Keep the liquid tank closed as much as possible; remove the caps immediately before assembly (There is a bag of drying agent in the condenser. This becomes soaked very quickly if the tank is left open and is rendered useless)
- Air conditioning with refrigerant R134a
- Inside the condenser that has been removed, there is refrigeration oil that must be added to the refrigeration circuit (with the new condenser).
- The quantity of oil is adjusted depending on the fault. If, for example, only the condenser has been damaged (no refrigerant has been lost and no damp or dirt has entered the refrigerant circuit), the air conditioning can be easily repaired by weighing the old and the new condensers (the new condenser should be topped up with refrigerant oil until it reaches the weight of the old condenser).
Parts & tools for this job For 1999 SEAT Toledo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Toledo 1999 cabin filter