Function test
Start engine.
Connect the compressor (select operating mode “Auto” on the control and display unit
- The compressor is on:
Disconnect the connector (B) from the switch.

The compressor remains off (low pressure switch, open).
Remove the switch (A) and connect connector (B).
The compressor remains off (low pressure switch, open).
- The compressor is off:
Disconnect connector (B) of switch (A) and bridge pins 1 and 2 of the connector between (B) the compressor comes on.
Note
- If the compressor comes on when the pins are bridged, or if the refrigerant pressure is too low ( the circuit is empty) or if the switch is faulty.
- To check the refrigerant pressure, take the vehicle to a support workshop specialised in SEAT air conditioners.
- F129 is displayed as a condition for disconnecting the compressor on the measured value block, find and remove the break in the electrical connection and the pressure switch F129 and the unit E87