Removing and fitting
- Make
- SEAT
- Model
- Toledo
- Year
- 1M, 1999–2004
- Section
- Heating, ventilation and air conditioning › Removing and fitting
Air conditionerRemoving and fitting
Removing and fitting
Detach connector.

Remove the pressure switch (B). Tightening torque: 5 Nm.
Replace the o-ring (A) (10.8 mm; 1.8 mm) Chapter “O-rings for refrigerant circuit”.
Note
- (B).

- The refrigerant circuit remains closed; the connection is fitted with a valve.
Parts & tools for this job For 1999 SEAT Toledo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Toledo 1999 cabin filter