Refrigeration agent circuit: repairs
- Make
- SEAT
- Model
- Toledo
- Year
- 1M, 1999–2004
- Section
- Heating, ventilation and air conditioning › Refrigeration agent circuit: repairs
‹ Prev Fault location in the event of divergence from theoretical valueNext › Condenser: removing and installing
Air conditionerRefrigeration agent circuit: repairs
Refrigeration agent circuit: repairs

Note
- 3)
- Chapter “Cooling capacity of the air conditioning: check”
- Do not top up with refrigerant in this circuit (completely drain the system, and refill)
- The stated diameters for the O-ring seals and the tightening torque also apply to refrigerant pipe unions between the individual components.
- Air conditioning with refrigerant R134a
- , or ) Spare parts programme.
- Chapter “Repair work on refrigerant circuit”.
- Air conditioning with refrigerant R134a
- Air conditioning with refrigerant R134a

- 1 Oil drain plug
O-ring seal: 8.8 mm; 1.5 mm (colour: black)
Tightening torques: 15 Nm Note To drain the refrigerant oil::Remove the compressor Remove the oil drain plug Turn the compressor using the clutch plate of the electromagnetic coupling in order to speed up the draining process - 2 Electromagnetic coupling N25
Repair Chapter “High-pressure sender G65 : check” - 3 Compressor
Removing and refitting the refrigerant tubes Chapter “Refrigerant pipes from the expansion valve removing and installing”⇒
Detaching and attaching compressor from support
Removing and fitting the compressor Chapter “Compressor: Removing and installing” Note Removing and fitting the ribbed belt Rep. group 10; Engine: removing and installing Mark the direction of operation of the belt before removing: switching the direction may lead to the destruction of the belt The stroke of the compressor piston is variable, it aalters according to the cooling capacity required If a new compressor has been fitted or this one has been filled with new refrigerant (e.g. after blowing the refrigerant circuit and draining the compressor using the oil drain plug), turn the compressor by hand 10 turns after assembly (to prevent damage to the compressor on use) - 4 High pressure release valve
O-ring seal: 8,6 mm; 1,8 mm (colour: black)
Tightening torques: 10 Nm.WARNING The connection is not fitted with a valve; the overpressure discharge valve should only be removed when the refrigerant circuit is empty - 5 Condenser
Removing and fitting Chapter “Condenser: Removing and installing” - 6 Condenser
Removing and fitting Chapter “Condenser: Removing and installing” - 7 Connection for service
High-pressure end
For the service station; for measurement, emptying and filling WARNING The service connections should only be removed when the refrigerant circuit is empty; the connection is not fitted with a valve - 8 Cap
On principle, fit with seal element - 9 Connection with valve
- 10 Air conditioner pressure switch F129
Operation, disassembling and assembling Chapter “Air conditioner pressure switch F129” - 11 Expansion valve
Removing and refitting the refrigerant tubes Chapter “Refrigeration agent pipes of the compressor: removing and installing”
Removing and fitting Chapter “Expansion valve: Removing and installing”
Removal and assembly of thermal insulation Item “Components for the control and adjustment of the air conditioner in the engine compartment, part 2ª” - 12 Evaporator
Removal and fitting air conditioning Chapter “Air conditioning heat exchanger: removing and installing”
Dismantling and assembling air conditioning Chapter “Air conditioner: dismantling and assembling”
Dismantling and assembling the evaporator housing Chapter “Evaporator housing: dismantling and assembling”. - 13 Cap
On principle, fit with seal element - 14 Connection for service
Low-pressure end
For the service station; for measurement and draining.WARNING The service connections should only be removed when the refrigerant circuit is empty; the connection is not fitted with a valve - 15 Collecting tank
Fitted on the refrigerant hose of the expansion valve to the compressor
On the collector tank, the pressure knocks which may arise on the low pressure side are reduced while the compressor is on.
‹ Prev Fault location in the event of divergence from theoretical valueNext › Condenser: removing and installing
Parts & tools for this job For 1999 SEAT Toledo
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.