Check condensation water drain
- Make
- Skoda
- Model
- Superb II
- Year
- 3T, 2008 on
- Section
- Heating, Air conditioning › Check condensation water drain
‹ Prev Removing and installing dust pollen filterNext › Removing and installing series resistor for fresh air blower with overheating fuse N24
Air conditionerCheck condensation water drain
Check condensation water drain
Remove the side cover on the front passenger side Body Work Rep. gr. 68.
Fold back the floor covering until the condensation water drain (4) is visible.

Cover the area below the opening (1) with absorbant paper.
Carefully pull off the connection angle (2) from the heating and air conditioning unit (1) and the connection (4) from the opening (5).
Check the condensation water drain (1) and (4) for contamination; e.g. with a piece of wire.
Note
- (2) and (4) must fit tightly on the pipe (3).
- (2) and (4) in the areas (1) and (5) (torsion stop).
‹ Prev Removing and installing dust pollen filterNext › Removing and installing series resistor for fresh air blower with overheating fuse N24
Parts & tools for this job For 2008 Skoda Superb
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Skoda Superb 2008 cabin filter