Removing and installing fresh air blower V2
- Make
- Skoda
- Model
- Superb II
- Year
- 3T, 2008 on
- Section
- Heating, Air conditioning › Removing and installing fresh air blower V2
‹ Prev Removing and installing heating element for additional air heating Z35Next › Removing and installing dust pollen filter
Air conditionerRemoving and installing fresh air blower V2
Removing and installing fresh air blower V2
Note
- fresh air blower V2 regulated by the series resistor is identical.
The fresh air blower V2 is accessible from the front passenger side of the footwell.
Remove shield (1) from heater unit Chapter “Summary of components”.

Separate plug connection (2) at the fresh air blower V2.
Unscrew screw (4) for fresh air blower V2 (if present).
Release catch (3) and turn fresh air blower V2 in direction of (arrow) and remove.
Installation is carried out in the reverse order.
Note
- (3) is defective, screw in screw (4) (1 Nm).
‹ Prev Removing and installing heating element for additional air heating Z35Next › Removing and installing dust pollen filter
Parts & tools for this job For 2008 Skoda Superb
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Skoda Superb 2008 cabin filter