Left-hand drive
- Make
- Skoda
- Model
- Superb II
- Year
- 3T, 2008 on
- Section
- Heating, Air conditioning › Left-hand drive
Left-hand drive
Switch off the ignition and all electrical components.
Remove the footwell vent on the driver's side Chapter “Remove and install footwell vent”.
Remove the control unit for data bus diagnostic interface J533 (attached in the area of the steering column to the bracket) Electrical System Rep. gr. 97.
Release screws ( 3 ) (10 Nm).

The screws (1) are not released.
Press the bracket (1) in the direction of the brake pedal (arrow) and fasten it there with the cable strap.

Mark the connector (C) (the design is identical to other connectors, danger of mix-ups) and subsequently remove it at the left temperature flap control motor V68 (B).

Removing cover (A).
Release the fixing screws (D) (1.4 Nm) and remove the control motor (B).
Slacken the lever (E) of the control motor from the coupling rod (F).
Installation is carried out in the reverse order.
Note
- After installing the control motor, it is necessary to test the operation of the left temperature flap.
- with the Vehicle diagnostic tester.