vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

DTC B048D or B048E > < DTC P0532 or P0533

DTC B0193

Diagnostic Instructions

•  Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
•  Review Strategy Based Diagnosis for an overview of the diagnostic approach.
•  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC B0193 01: Front Blower Motor Speed Circuit Short to Battery
DTC B0193 06: Front Blower Motor Speed Circuit Low Voltage/Open

Diagnostic Fault Information



Circuit


Short to Ground


Open/High Resistance


Short to Voltage


Signal Performance


Blower Motor Control Module B+


B0193 06


B0193 06


-


-


Blower Motor B+


1


1


-


-


Blower Motor Control Module Control


B0193 06


B0193 06


B0193 01


-


Blower Motor Control


2


1


1


-


Blower Motor Control Module Ground


-


1


-


-


1. Blower Motor Inoperative

2. Blower Motor Always ON

 

Circuit/System Description

The blower motor control module is an interface between the HVAC control module and the blower motor. The blower motor speed control from the HVAC control module, battery positive and ground circuits enable the blower motor control module to operate. The HVAC control module provides a pulse width modulation (PWM) signal to the blower motor control module in order to command the blower motor speed. The blower motor control module transfers the PWM signal into a corresponding blower motor voltage. The voltage resides between 2-13 V and changes linear to the height of the PWM signal.

Conditions for Running the DTC

•  Ignition ON.
•  The HVAC control module is ON.

Conditions for Setting the DTC

B0193 01

The voltage at the HVAC control module output to the blower motor control module is always high.

B0193 06

The voltage at the HVAC control module output to the blower motor control module is always low or floating.

Action Taken When the DTC Sets

The blower motor is inoperative.

Conditions for Clearing the DTC

The condition for setting the DTC is no longer present.

Reference Information


Schematic Reference

HVAC Schematics


Connector End View Reference

Component Connector End Views


Description and Operation

Manual HVAC Description and Operation


Electrical Information Reference


Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

1. Ignition OFF, disconnect the X1 harness connector at the K8 Blower Motor Control Module, ignition ON.
2. Verify that a test lamp illuminates between the B+ and ground circuit terminal 5 X1.
    ⇒  If the test lamp does not illuminate

Repair the open/high resistance in the circuit.     ⇓  If the test lamp illuminates

3. Verify that a test lamp illuminates between the B+ circuit terminal 6 X1 at the K8 Blower Motor Control Module harness connector and ground.
    ⇒  If the test lamp does not illuminate and the circuit fuse is good

  3.1 Ignition OFF.
  3.2 Test for less than 2 Ω in the B+ circuit end to end.
⇒  If 2 Ω or greater, repair the open/high resistance in the circuit.
⇒  If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
    ⇒  If the test lamp does not illuminate and the circuit fuse is open

  3.1 Ignition OFF.
  3.2 Test for infinite resistance between the B+ circuit and ground.
⇒  If less than infinite resistance, repair the short to ground on the circuit.
⇓  If infinite resistance
  3.3 Disconnect the X2 harness connector at the K8 Blower Motor Control Module.
  3.4 Test for infinite resistance between the B+ circuit terminal 1 X2 and ground.
⇒  If less than infinite resistance, replace the M8 Blower Motor.
⇓  If infinite resistance
  3.5 Install a jumper wire between the ground circuit terminal 2 X2 and ground.
  3.6 Install a 40 A fused jumper wire between the B+ circuit terminal 1 X2 and B+ and verify the fuse is good.
⇒  If the fuse is open, replace the M8 Blower Motor.
⇒  If the fuse is good, replace the K8 Blower Motor Control Module.
    ⇓  If the test lamp illuminates

4. Ignition OFF, disconnect the X2 harness connector at the K33 HVAC Control Module, ignition ON.
5. Test for less than 0.3 V between the control circuit terminal 3 X1 at the K8 Blower Motor Control Module harness connector and ground.
    ⇒  If greater than 0.3 V

Repair the short to voltage on the circuit.     ⇓  If less than 0.3 V

6. Ignition OFF.
7. Test for infinite resistance between the control circuit terminal 3 X1 at the K8 Blower Motor Control Module harness connector and ground.
    ⇒  If less than infinite resistance

Repair the short to ground on the circuit.     ⇓  If infinite resistance

8. Test for less than 5 Ω between the K33 HVAC Control Module control circuit terminal 15 X2 and control circuit terminal 3 X1 at the K8 Blower Motor Control Module harness connector.
    ⇒  If 5 Ω or greater

Repair the open/high resistance in the circuit.     ⇓  If less than 5 Ω

9. Replace the K8 Blower Motor Control Module and verify the DTC does not reset.
    ⇒  If DTC resets

Replace the K33 HVAC Control Module.     ⇓  If DTC does not reset

10. All OK.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

•  Control Module References for HVAC control module replacement, programming and setup

DTC B048D or B048E > < DTC P0532 or P0533