01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Alfa Romeo 147 Factory Service Manual (2000-2004)22 · Fault diagnosis
22 · Diagnostics

Battery charging warning light not working

Make
Alfa Romeo
Model
147 Factory Service Manual
Year
2000–2004
Section
Instrument panel › Battery charging warning light not working
Fault diagnosisBattery charging warning light not working

BATTERY CHARGING WARNING LIGHT NOT WORKING

When the ignition is turned on, the generator warning light does not come on.

Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the Examiner to the diagnostic socket

Check warning light operation while in active diagnosis mode

Continue to Step 2The warning light does not come onReplace instrument panel Op. 5560B11
2CHECKING ELECTRICAL EQUIPMENTAll OKProblems metOperation
Check body computer power supply is correct, particularly the D+ and +15 signal: See E5010 STARTING AND RECHARINGContinue to Step 3Body computer power supply incorrect.Restore correct power supply
3CHECKING BATTERYAll OKProblems metOperation
Check the operation of the battery.Continue to Step 4Battery not workingReplace the battery Op. 5530B10
4CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'