BATTERY CHARGING WARNING LIGHT NOT WORKING
When the ignition is turned on, the generator warning light does not come on.
| Results of the tests | ||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the Examiner to the diagnostic socket Check warning light operation while in active diagnosis mode | Continue to Step 2 | The warning light does not come on | Replace instrument panel Op. 5560B11 | |
| 2 | CHECKING ELECTRICAL EQUIPMENT | All OK | Problems met | Operation |
| Check body computer power supply is correct, particularly the D+ and +15 signal: See E5010 STARTING AND RECHARING | Continue to Step 3 | Body computer power supply incorrect. | Restore correct power supply | |
| 3 | CHECKING BATTERY | All OK | Problems met | Operation |
| Check the operation of the battery. | Continue to Step 4 | Battery not working | Replace the battery Op. 5530B10 | |
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | Fault persists | Search for the fault starting from another symptom' | ||
‹ Prev Minimum engine oil pressure warning light not workingNext › I.e. failure warning light and code warning light both off / engine does not start
Parts & tools for this job For 2000 Alfa Romeo 147
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.