Workshop Manuals Factory service & repair Alfa Romeo
01 General data and specifications02 Maintenance03 Diagnosis – checks04 Engine (1.6 and 2.0 Twin Spark)05 Clutch06 Gearbox (manual and Selespeed)07 Front axle08 Brakes, ABS and traction control09 Steering10 Suspension and wheels11 Heating, air conditioning and washers12 Electrical equipment13 Body14 Body panels and reinforcement15 Wiring diagrams16 Connectors and pin-outs17 Wiring harnesses18 Fault diagnosis19 Special tools
Alfa Romeo 147 Factory Service Manual (2000-2002)18 · Fault diagnosis
18 · Diagnostics

F10 Excessive brake pedal stroke

Make
Alfa Romeo
Model
147 Factory Service Manual
Year
2000–2002
Section
Brakes › F10 Excessive brake pedal stroke
Fault diagnosisF10 Excessive brake pedal stroke

F10 Excessive brake pedal stroke

When the brake pedal is depressed, its travel is longer than the normal operating travel.

StepTest procedureResultAction
1CHECKING BRAKE PEDAL SOFTNENSS

Check that the brake pedal is not soft

Check brake fluid level

Check that there are no fluid leaks from: connectors, pipes, hoses, brake adjuster, reservoir, wheel cylinders, master cylinder

Check that the flexible couplings expand under the braking action

OK

Move onto step 2

Pedal soft

End of diagnosis

Pedal soft
  • Tighten the connectors or replace the part generating the leak, then top up to the medium level Op. 3330A10

End of diagnosis

Pedal soft
  • Move on to Step 2

End of diagnosis

Pedal soft
  • Replace hoses

End of diagnosis

2CHECK BRAKE PEDAL

Check that the brake pedal does not have two pressure stages and that it returns promptly

OK

Move onto step 3

The pedal jumps: one chamber is not holding pressure

End of diagnosis

The pedal jumps: one chamber is not holding pressure

End of diagnosis

The pedal jumps: one chamber is not holding pressure

End of diagnosis

The pedal jumps: one chamber is not holding pressure

End of diagnosis

3CHECKING EFFICIENCY OF HANDBRAKE SELF-ADJUSTER

Check the efficiency of the handbrake self-adjuster, by pulling the handbrake

OK

Move onto step 4

Device faulty
  • Change the device

End of diagnosis

4CHECKING BRAKE PEDAL SOFTNESS

Check whether the pedal becomes too soft after several braking actions (Vapour loop)

OK

Move onto step 5

The pedal becomes soft

End of diagnosis

The pedal becomes soft

End of diagnosis

5CHECKING HOLE ON BRAKE FLUID RESERVOIR

Check that the hole in the brake fluid reservoir is not blocked

OK

Move onto step 6

Hole blocked
  • Clean reservoir hole

End of diagnosis

6CHECKING CORRECT OPERATION

Test the vehicle before delivery to the customer, to check that the fault is no longer present

NOTE: The test is essential, as the braking system involves a safety feature of the car

OK

Incorrect selection of diagnostic procedure

Fault persists

Incorrect selection of diagnostic procedure

Parts & tools for this job For 2000 Alfa Romeo 147

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.