Capacities
- Make
- Audi
- Model
- A6 C6
- Year
- 2004–2011
- Section
- Servicing refrigerant circuit › Capacities
Air conditioningCapacities
Capacities
Refrigerant R134a and refrigerant oil capacities Air conditioner with refrigerant R134a
Evacuating and filling refrigerant circuit Air conditioner with refrigerant R134a.
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the notes on start-up of the air conditioner after charging Air conditioner with refrigerant R134a.
- Always fill refrigerant circuit as far as upper tolerance limit (some refrigerant remains in filler hoses) Air conditioner with refrigerant R134a.
- The refrigerant circuit is only to be filled with approved refrigerant oils Electronic parts catalogue. Different types of refrigerant oil are specified for Zexel, Sanden and Denso compressors Air conditioner with refrigerant R134a and Electronic parts catalogue.
- The refrigerant oil G 052 300 A2 is currently to be used for Denso compressors Electronic parts catalogue and Air conditioner with refrigerant R134a.
- Refrigerant oil (PAG oil) from containers which have been open for a long time absorbs moisture and is no longer to be used.
- The condenser fitted on vehicles with a 10-cyl. TFSI engine (Audi RS6) has a smaller internal volume than the condenser with other engines. For vehicles with a 10-cyl. TFSI engine the refrigerant capacity is thus also slightly less than for other vehicles Electronic parts catalogue and Air conditioner with refrigerant R134a.
- Further information Air conditioner with refrigerant R134a
Parts & tools for this job For 2004 Audi A6
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A6 2004 cabin filter
As an Amazon Associate we earn from qualifying purchases.