Removing and installing restrictor
- Make
- Audi
- Model
- A6 C6
- Year
- 2004–2011
- Section
- Servicing refrigerant circuit › Removing and installing restrictor
Removing and installing restrictor
Note
- This vehicle is only to be fitted with a red coloured restrictor (depending on the manufacturer, the colour may also tend towards orange) Electronic parts catalogue and Air conditioner with refrigerant R134a.
- Differently coloured replacement restrictors are available (“yellow” restrictor, diameter of bore/constriction 1.54 mm; “red” restrictor, diameter of bore/constriction 1.42 mm). Attention is therefore to be paid to assignment (different refrigerant circuit matching).
- There are different types of refrigerant pipe between evaporator and compressor/reservoir depending on vehicle model Electronic parts catalogue
Drain refrigerant circuit Air conditioner with refrigerant R134a.
Detach refrigerant pipe at screw connection (A) (seal open connections).
Use pointed-nose pliers to pull restrictor (B) out of refrigerant pipe.

Note
- Only fit restrictors of the same type. Restrictors of different colour have different bore diameters: Electronic parts catalogue
Check correct positioning of O-ring (C) (7.5 mm; 1.5 mm) in groove.

Before fitting, moisten the O-ring (of the restrictor and at the screw connection) with a small quantity of refrigerant oil → Chapter.
Ensure correct positioning of restrictor (B) on installation (arrow on restrictor pointing towards evaporator).
Check positioning of restrictor (snug fit in refrigerant pipe).
Replace the O-ring (D), for version, refer to Electronic parts catalogue.
Install refrigerant pipes such that they are not strained.
Tighten the screw connection (A).
Tightening torque: 15 Nm.Note
- Check position of refrigerant pipes after tightening screw connection (pipes must not make contact with other components).
Evacuate and re-fill refrigerant circuit Air conditioner with refrigerant R134a.
Interrogate the fault memory of the operating and display unit, Climatronic control unit J255 and erase any faults displayed "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the notes on start-up of the air conditioner after charging Air conditioner with refrigerant R134a.
Parts & tools for this job For 2004 Audi A6
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A6 2004 cabin filter