Servicing refrigerant circuit
- Make
- Audi
- Model
- A6 C6
- Year
- 2004–2011
- Section
- Servicing refrigerant circuit › Servicing refrigerant circuit
Air conditioningServicing refrigerant circuit
Servicing refrigerant circuit

- Air conditioning system compressor regulating valve N280
Checking actuation and operation → Chapter
Not to be removedNoteAir conditioning system compressor regulating valve N280 is actuated by operating and display unit, Climatronic control unit J255 and controls pressure on low-pressure end of refrigerant circuit. - Compressor
Different versions depending on the engine Electronic parts catalogue
Detaching compressor with pulley from holder/re-attaching → Chapter
Detaching compressor with drive unit (shaft) from holder/re-attaching → Chapter
Detaching refrigerant pipe at compressor/attaching → Chapter
Detaching poly V-belt Engine, mechanicsRep. Gr.13
Removing and installing compressor (vehicles with 4 or 6-cyl. engine) → Chapter
Removing and installing compressor (vehicles with 8-cyl. engine) → Chapter
Removing and installing compressor (vehicles with 10-cyl. engine) ChapterNoteTo protect compressor, engine is only to be started following complete assembly of refrigerant circuit.When installing refrigerant pipes and corresponding holder, make sure there is sufficient distance between belt, holder and pulley.After installing compressor and before fitting belt/screwing in drive shaft, crank compressor roughly 10 times by hand (to prevent compressor damage). Any refrigerant oil which may have collected in the compression chamber on removing the compressor or after pouring in fresh refrigerant oil (e.g. after purging the refrigerant circuit) is forced out of the compression chamber by the cranking action. - Pulley/drive unit for compressor
Different versions depending on the engine Electronic parts catalogue
Replacing compressor pulley → Chapter
Removing and installing poly V-belt Engine, mechanicsRep. Gr.19
Poly V-belt assignment: Electronic parts catalogue
Replacing compressor drive unit ChapterNoteAn overload safeguard is fitted between the pulley/drive unit and the drive shaft of the compressor to protect the belt/engine if the compressor becomes jammed or stiff.If compressor is not operating smoothly, overload safeguard interrupts power transmission to compressor.Rubber elements are fitted between pulley/drive unit and compressor drive shaft to cushion any vibration occurring during compressor operation (damper function in the event of torque fluctuations). - Oil drain plug
The Denso compressor is fitted with an oil seal which has to be replcaced Electronic parts catalogue
Tightening torque: 30 Nm
Compressor must be removed before screwing out to drain off refrigerant oil. Crank compressor by way of pulley/drive unit to accelerate drainage of refrigerant oil Air conditioner with refrigerant R134a. - Pressure relief valve
Not to be removed
Tightening torque: 10 Nm - Condenser
Detaching and re-attaching refrigerant pipes → Chapter
Removing and installing condenser → Chapter
Different versions Electronic parts catalogue - Connection with valve
Use an adapter from the adapter set for service connections T10364 for example for removing and installing the valve insert with the refrigerant circuit drained.WARNINGThe refrigerant circuit must always be drained before removing the valve insert. - Refrigerant pressure/temperature sender G395
Removing and installing → Chapter
Housing colour “Grey”
Checking signal "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051NoteThe measured values for the refrigerant pressure/temperature sender G395 can be read out by way of the “Reading measured value block” function in two display groups "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.The refrigerant pressure/temperature sender G395 exchanges information by way of the air conditioner data bus system “Lin bus” with the operating and display unit, Climatronic control unit J255. The Audi A6 is therefore not to be fitted with a high-pressure sender G65 (only emits square-wave signals) Electronic parts catalogue.On account of the design of the refrigerant pressure/temperature sender G395 and its fitting location, the temperature measured by the refrigerant pressure/temperature sender G395 differs from the actual temperature of the refrigerant in the refrigerant circuit. At present this is therefore not evaluated and used for air conditioner regulation "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. - Service connection
High-pressure end
For service station for measuring, draining and filling Air conditioner with refrigerant R134a
For measurement, drainage and filling; the vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a
Different versions (with primary sealing valve or Schrader valve) depending on refrigerant pipe; distinguishing features Air conditioner with refrigerant R134a
Use an adapter from the adapter set for service connections T10364 for example for removing and installing the service connection or valve insert with the refrigerant circuit drained.WARNINGRefrigerant circuit must be drained before removing service connections (connection has no valve). - Cap
With seal
Always to be screwed on - Screw connection in refrigerant pipe (with restrictor)
Replace O-ring, version Electronic parts catalogue
Tightening torque: 15 Nm
Refrigerant circuit must be drained before opening screw connection - Restrictor
Fitted in screw connection Item
O-ring: 7.5 mm / 1.5 mm
Replace restrictor with O-ring Electronic parts catalogue
Removing and installing → Chapter
Moisten O-ring slightly with refrigerant oil before fitting restrictor - Refrigerant pipe screw connection at air conditioner unit
The screw connection is only to be unfastened after draining the refrigerant circuit; the vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a.
Detaching refrigerant pipe to air conditioner unit/attaching → Chapter - Refrigerant pipe screw connection (at evaporator)
Unfastening and assembling screw connection → Chapter (removing and installing evaporator)
Tightening torque: Hexagon socket-head bolt 25 Nm
The screw connection is only to be unfastened after draining the refrigerant circuit; the vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a. - Evaporator
Removing and installing evaporator → Chapter
Replace O-rings, version Electronic parts catalogue
Detaching refrigerant pipe to air conditioner unit/attaching → Chapter - Service connection
Low-pressure end
For service station for measurement and drainage Air conditioner with refrigerant R134a
For measurement and drainage; the vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a
Different versions (with primary sealing valve or Schrader valve) depending on refrigerant pipe; distinguishing features Air conditioner with refrigerant R134a
Use an adapter from the adapter set for service connections T10364 for example for removing and installing the service connection or valve insert with the refrigerant circuit drained.WARNINGRefrigerant circuit must be drained before removing service connections (connection has no valve). - Cap
With seal
Always to be screwed on - Reservoir
Different versions Electronic parts catalogue
Replace O-rings, version Electronic parts catalogue
Moisten O-rings slightly with refrigerant oil before fitting
Tightening torque: Hexagon socket-head bolt at block connection: 10 Nm
Removing and installing → Chapter
Parts & tools for this job For 2004 Audi A6
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A6 2004 cabin filter