Note
- There are different reservoir versions depending on vehicle model Electronic parts catalogue
- Up to 09.2004, use was made of reservoir holders which may transmit noise to the bodywork under certain usage conditions in air conditioner operation (howling noise from the engine compartment caused by holder vibration in air conditioning mode). As of 09.2004, production was gradually switched to an optimised holder (G)Electronic parts catalogue.

- If vehicles manufactured up to 09.2004 are fitted with an optimised holder (G), it may be necessary to remove the double bolt to which the nut (B) is attached, turn it through 180 ° and then re-install (the longer side must face the holder). It may also be necessary to use a longer version of the bolts (A).
Drain refrigerant circuit Air conditioner with refrigerant R134a.
Remove front bumper cover General body repairs, exteriorRep. Gr.63.
Remove the left headlight Electrical systemRep. Gr.94.
Remove the charge air cooler Engine, mechanicsRep. Gr.21.
Screw out bolts (A) and detach refrigerant pipes (B) and (C).

Note
- Depending on the version it may also be possible to remove the reservoir without the holder (the bolts (A) and the nut (B) are then not to be unfastened).
- Depending on the problem and the version, it may also be possible to remove the reservoir without the holder. In this case (Items A, B, C, F) can be ignored.

Remove the bolts (A) and the nut (B) (only if the holder (G) is to be removed).
Unfasten the holder (F) of the refrigerant pipe from the holder (G) (only if the holder (G) is to be removed).
Detach the reservoir (E) with the holder (G) (only if the holder (G) is also to be removed).
Slacken off bolts (D) and remove reservoir (E) from holder (G).
Note
- Seal the open connections at the reservoir and the pipe connections with suitable caps (to prevent the ingress of dirt and moisture).
- The design of the reservoir and attachment of the refrigerant pipes differ depending on the engine version: Electronic parts catalogue
- The reservoir removed contains refrigerant oil which has to be returned to the refrigerant circuit Air conditioner with refrigerant R134a.
- Before fitting reservoir Air conditioner with refrigerant R134a
Note
- The removed reservoir contains refrigerant oil which has to be returned to the refrigerant circuit (with new reservoir). Adjustment of the oil quantity depends on the nature of the problem. If, for example, reservoir has been damaged in an accident (no loss of refrigerant, no ingress of moisture and dirt into refrigerant circuit), air conditioner can be serviced by weighing old and new reservoir without the need for extensive repair work. Pour refrigerant oil into new reservoir until it weighs the same as the reservoir removed Air conditioner with refrigerant R134a.
- Keep new reservoirs closed for as long as possible, only remove the caps immediately before installation (the reservoir contains a desiccant bag which soon becomes saturated with moisture and hence unusable when the reservoir is open).
- If for example in the case of an accident involving refrigerant, an indeterminate amount of refrigerant oil has escaped or dirt and moisture have ingressed into the refrigerant circuit, clean (purge) the refrigerant circuit Air conditioner with refrigerant R134a.
- Connections at reservoir may be marked “IN” (from evaporator) and “Out” (to compressor).
Install in reverse order, paying attention to the following:
Insert reservoir (E) in holder (G), paying attention to locking and locating element (J).

Tighten bolts (D).
Tightening torque: 10 Nm.Attach washer (C) to pin (H).
Install the reservoir (E) with the holder (G).
Fit the bolts (A) and the nut (B).
Tightening torque: 10 Nm.Replace O-rings (D) and (E), version Electronic parts catalogue

Check guide ring (H) at connections of both refrigerant pipes (B) and (C) for damage.
Insert appropriate O-ring ((D) and (E)) in groove (J) at connections of both refrigerant pipes (B) and (C).
Note
- Moisten the O-rings slightly with refrigerant oil before fitting → Chapter.
Fit refrigerant pipes (B) and (C).
Fit the bolts (A).
Tightening torque: 10 Nm.Following attachment, check the routing of the refrigerant pipes. They must be inserted in the holders provided and not make contact with other components.
Re-install the other components removed.
Evacuate and refill the refrigerant circuit Air conditioner with refrigerant R134a.
Interrogate the fault memory of the operating and display unit, Climatronic control unit J255 and erase any faults displayed "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the notes on start-up of the air conditioner after charging Air conditioner with refrigerant R134a.