Before fitting evaporator Air conditioner with refrigerant R134a
Install in reverse order, paying attention to the following:
Clean mounting slot for evaporator in air conditioner unit (A).

Check both connections (C) and (D) in evaporator connecting flange of refrigerant pipes (B) for dirt and damage and clean if necessary.
Note
- Replacement of refrigerant pipes (B) with evaporator connecting flange involves removing air intake unit and detaching refrigerant pipes to air conditioner unit. Coolant pipes to heat exchanger on left side must also be detached/removed (refer to notes for right-hand drive vehicles → Chapter).
Before fitting evaporator, check openings of condensate drains (F) (on left and right in air conditioner unit) for dirt and clean if necessary.
Attach plastic tray (C) to evaporator (A).

Attach all-round rubber seal (B) to evaporator (A), paying attention to correct positioning at evaporator connecting flange (D).
Replace the O-rings (E) and (F) at the connections (D) at the evaporator (A), version Electronic parts catalogue.
Note
- Moisten O-rings with small quantity of refrigerant oil before installing.
- Pay attention to correct positioning of O-rings (E) and (F) in groove in connecting pipes at evaporator connecting flange (D).
- The evaporator removed contains refrigerant oil, which must be returned to refrigerant circuit Air conditioner with refrigerant R134a.
Moisten rubber seal (B) at bottom and top of evaporator with a small quantity of lubricant (e.g. soap solution).
Carefully install the evaporator (E) in the slot (A) of the air conditioner unit, taking care not to damage the evaporator connections.

Check position of evaporator connecting flange (D) (must be flush with housing of air conditioner unit (A)).
Check connecting flange of refrigerant pipes (C) and connecting flange at evaporator (D) for dirt and damage.

Assemble connecting flange (C) (of refrigerant pipes) and connecting flange (D) at evaporator (E).
Fit bolts (B) (tightening torque 10 Nm).
Re-insulate connecting flange area at evaporator (from which insulation has been detached) with a section of self-adhesive thermal insulation mat (A).
Note
- This thermal insulation mat is available as a replacement part Electronic parts catalogue.
Fill groove (B) in bottom part of service cover (A) with silicone adhesive sealant D176 001 A3 for example.

Note
- Replacement service covers (A) are available with 7 bolts (C)Electronic parts catalogue.
- If air conditioner unit/service cover connection is not sealed, condensate may escape from air conditioner unit into footwell for example when cornering.
Fit service cover (A) over evaporator slot of air conditioner unit.
Re-install components removed in reverse order except lower dash panel trim (driver's side), glove box and plenum chamber cover.
Note
- Bleed the coolant circuit before plugging in the 2-pin connector to the coolant circulation pump V50 of the pump valve unit.
- The coolant circuit must be bled before starting up the coolant circulation pump V50 (in the pump valve unit).
- Dry running of pump in pump valve unit would lead to destruction.
Filling and bleeding coolant circuit Engine, mechanicsRep. Gr.19
Note
- When bleeding coolant circuit, take particular care to ensure complete bleeding of heat exchangers. If air bubbles remain in heat exchanger, complaints may be received about lack of heat output in winter or differences in temperature of air flowing out of vents with same setting in control mode.
After bleeding, check cooling system for leaks, paying particular attention to coolant pipe joints to heat exchanger Engine, mechanicsRep. Gr.19.
Check correct positioning of sockets in coolant pipe penetrations from plenum chamber to passenger compartment.
Following installation, check correct positioning of the socket between the engine compartment and plenum chamber at the coolant hose (C).

Check pump valve unit; it must not make contact with other components (noise).
Plug in connectors (D) to left heat regulation valve N175 and right heat regulation valve N176 and (E) to coolant circulation pump V50 after bleeding coolant circuit.
Evacuate and re-fill refrigerant circuit Air conditioner with refrigerant R134a.
After filling refrigerant circuit, check refrigerant pipe joints in plenum chamber and at evaporator for leaks e.g. with an electronic leak detector Air conditioner with refrigerant R134a.
Remove residual coolant from plenum chamber.
Re-install remaining components removed in reverse order.
Interrogate fault memory of operating and display unit, Climatronic control unit J255 and erase any faults displayed "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the notes on start-up of the air conditioner after charging Air conditioner with refrigerant R134a.
Parts & tools for this job For 2004 Audi A6
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A6 2004 cabin filter
As an Amazon Associate we earn from qualifying purchases.