Removing
Perform preparatory work for evaporator removal → Chapter.Detach heat insulation (A) from connecting flange of refrigerant pipes at evaporator (E) (on left of air conditioner unit).

Remove bolts (B).
Detach connecting flange (C) (of refrigerant pipes) from connecting flange (D) (at evaporator (E)).
Slacken off bolt (A) at holder for coolant pipes (on right of air conditioner unit, do not remove) and lay aside coolant pipe (D).

Don cut-proof gloves (to protect the hands when cutting out the housing wall of the air conditioner unit).
Use sharp knife (e.g. strong pointed carpet knife with blade safely and firmly attached in handle) to cut housing wall (B) and (C) (on right of air conditioner unit) at parting line (E) out of air conditioner unit (for right-hand drive vehicles, refer to notes → Chapter).
Note
- Take care not to damage flange (F) (seals air conditioner unit service cover).
Pull evaporator (E) to right out of air conditioner unit.

Note
- If evaporator is stuck in air conditioner unit because of the all-round rubber seal, remove dust and pollen filter if necessary → Chapter to gain a firmer grip on evaporator.
Parts & tools for this job For 2004 Audi A6
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A6 2004 cabin filter
As an Amazon Associate we earn from qualifying purchases.