01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Croma Factory Service Manual (2005-2010)08 · Engine
08 · Engine

Variable geometry turbocharger actuator leakage test

Make
Fiat
Model
Croma Factory Service Manual
Year
2005–2010
Section
Engine supercharging system › Variable geometry turbocharger actuator leakage test
EngineVariable geometry turbocharger actuator leakage test

VARIABLE GEOMETRY TURBOCHARGER ACTUATOR LEAKAGE TEST

Check 1064BC

1.9 JTD 8v, 1.9 JTD 16v, 2.4 JTD 20v

Visually inspect that during start-up, the turbocharger actuator connecting rod (turbine stator vanes adjustment device) moves by around 10 mm in the direction of the actuator.

With the engine switched off, connect connector EX09 and transducer EX06 in the section of pipe between the actuator and the solenoid valve.

Select intake pressure measuring gauge in instrument mode.

Start up the engine and let it idle, then wait until pressure pressure stabilizes.

The reading should not exceed 450-550 mmHg.

The graphic acquisition of the pressure trend can be carried out by selecting either the 2000 or 4000 mmHg scale.