Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Croma Factory Service Manual (2005-2010)22 · Fault diagnosis
22 · Diagnostics

Alarm volumetric surveillance not working

Make
Fiat
Model
Croma Factory Service Manual
Year
2005–2010
Section
Alarm › Alarm volumetric surveillance not working
Fault diagnosisAlarm volumetric surveillance not working

ALARM VOLUMETRIC SURVEILLANCE NOT WORKING

When the alarm is switched on using the remote control, the system is activated correctly but the volumetric sensors do not intervene.

The volumetric sensors are located in the courtesy light module and are connected to the Body Computer Node via the dialogue line known as the A-BUS. The volumetric sensors are operated and controlled by the Body Computer node by means of a series of coded messages and can be excluded by the customer using the special button. If there is a failure the Body Computer Node detects and memorizes the causes of the malfunction

Results of the tests
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation

Connect the diagnostic equipment to the diagnostic socket and check the following at the Body Computer Node in parameters ambient:

. the presence of the volumetric sensors in the errors ambient:

. that there are no faults with the volumetric sensors

Move on to Step 2Volumetric sensors manually excludedSwitch on the volumetric sensors after getting permission from the customer
Volumetric sensors not presentCheck the conformity of the vehicle
Presence of faultsProceed as instructed by the diagnostic tester
2ULTRASOUND MODULE POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check that the ultrasound module is correctly suppliedMove on to Step 3Supply not correctRestore correct power supply
3CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation

Connect the diagnostic equipment to the diagnostic socket and check the following at the Body Computer Node in active diagnosis:

- the operation of the volumetric modules

- the condition of the A-Bus serial line

Move on to Step 4A-BUS serial line interruption

Restore the serial line

See E7015 ALARM

Ultrasound module defective

Replace the courtesy light module with built in ultrasound sensors

Op. 7040E51 FRONT MODULAR COURTESY LIGHT ASSEMBLY - R R FOR VERSIONS WITH SUN-ROOF

4CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that the fault is no longer presentFault persistsBody Computer defective

Replace Body Computer

Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.

Parts & tools for this job For 2005 Fiat Croma