DiagnosisL50 Fan does not work
Diagnosis table
L50 Fan does not work
The passenger compartment fan does not work.
If the fan works, but speed is not as required, see table L51
| Step | Validity | Operation to be performed | Test results | ||
|---|---|---|---|---|---|
| All OK | Problems found | Intervention | |||
| 1 | CHECK CLIMATE CONTROL FAN ELECTRIC CIRCUIT Check in sequence: – fan fuse (F24) – fan – fan controls – adjustment resistance – connections between junction unit and fan – connection between fan and respective controls, via the adjustment resistance (Wiring diagram: E6010 "Heater") |
Go to Step 2 | Incorrect connections | Restore connections | |
| Faulty component | Replace component (if it is a fuse, investigate the causes which may have triggered it) | ||||
| Faulty fan | Replace fan PROCEDURE OP. 5020A34 |
||||
| 2 | CHECK CORRECT OPERATION Check the fault is no longer present |
All OK End of test |
– | – | |