Diagnosis table
- Make
- Fiat
- Model
- Seicento Factory Service Manual
- Year
- 1998–2010
- Section
- Climate control › Diagnosis table
DiagnosisDiagnosis table · page 1 of 3
Diagnosis table
L10 Climate control does not cool
The fan sends air to the passenger compartment normally but this air is sent at outside temperature and is not cooled.
NOTE: Cooling circuit engagement enabling is controlled by both the climate control ECU and the engine ECU. Therefore, if the climate control does not cool under certain particular conditions, this is correct.
For further details, see DESCRIPTION AND OPERATION 1056 and DESCRIPTION AND OPERATION 5040
| Step | Validity | Operation to be performed | Test results | ||
|---|---|---|---|---|---|
| OK | ⚠ | 🔧 | |||
| 1 | CHECK SYSTEM PRESSURE Check system pressure: TESTS: 5040 Test B |
All OK Go to Step 7 |
Problems found Pressure does not change: the compressor does not work |
Intervention Go to Step 2 |
|
| High pressure does not rise or low pressure falls too much: insufficient fluid | Recharge the system: PROCEDURE OP. 5040A10. Go to Step 6 | ||||
| High pressure keeps rising: too much fluid | Recharge the system: PROCEDURE OP. 5040A10. Go to Step 6 | ||||
| 2 | CHECK WITH DIAGNOSTIC TOOL Connect the diagnostic tool (Examiner or other tool) to the diagnostic socket – Check there are no errors in the engine ECU – Plausibility of all parameters |
All OK Go to Step 3 |
Problems found Error detected in the ECU |
Intervention Continue as shown by the diagnostic tool |
|
| No dialogue with ECU | Restore: – connection between engine ECU and diagnostic socket (Wiring diagram: E5030 “Petrol engine electronic engines”) |
||||
(Cont..)
Parts & tools for this job For 1998 Fiat Seicento
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Fiat Seicento 1998 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.