L51 Fan does not work at all speeds
The passenger compartment fan works but not at all speeds.
| Step | Validity Operation to be performed | Test results | ||
|---|---|---|---|---|
| All OK | Problems found | Intervention | ||
| 1 | CHECK CLIMATE CONTROL FAN ELECTRIC CIRCUIT | Go to Step 2 |
Incorrect connections | Restore connections |
| Check in sequence: – fan adjustment resistance – fan controls – connection between fan and respective controls, via the adjustment resistance (Wiring diagram: E6010 “Heater”) |
Faulty fan | Replace fan PROCEDURE OP. 5020A34 |
||
| Faulty fan adjuster | Replace fan resistor PROCEDURE OP. 5020A44 |
|||
| Faulty fan controls | Replace fan controls PROCEDURE OP. 5020A40 |
|||
| 2 | CHECK CORRECT OPERATION | All OK | Problems found | Intervention |
| Check the fault is no longer present | End of test | – | – | |