Workshop Manuals Factory service & repair Fiat
01 00 General information and technical data02 10 Engine03 18 Clutch04 21 Gearbox and differential05 27 Axle06 33 Braking system07 41 Steering08 44 Suspension and wheels09 50 Auxiliary units10 55 Electrical equipment11 70 Bodywork12 Diagnosis13 Tests14 Wiring diagrams
Fiat Seicento Factory Service Manual (1998-2010)12 · Diagnosis
12 · Diagnostics

Diagnosis table K52

Make
Fiat
Model
Seicento Factory Service Manual
Year
1998–2010
Section
On-board instruments › Diagnosis table K52
DiagnosisDiagnosis table K52

Diagnosis table K52

Code fault warning light on

When the engine is started, the “code” warning light stays on for longer than 0.7 seconds (after running the ECU initial test, the warning light should turn off)

The “E.I. fault” warning light comes on and turns off correctly

If at the same time the “E.I. fault” warning light stays on, see table K51

If at the same time the “E.I. fault” warning light does not come on when the engine is started, see table K54

StepValidityOperation to be performedTest results
OKProblems foundIntervention
1 CHECK WITH DIAGNOSTIC TOOL
Connect diagnostic tool (Examiner or other tools) to the diagnostic socket.
Check:
- no errors in the CODE ECU
All OK
Go to Step 2
Failed dialogue with the ECU Restore connection between CODE ECU and diagnostic socket
(Wiring diagram E7010 "CODE")
Error detected in ECU Continue as shown by the diagnostic tool
2 CHECK CORRECT OPERATION
Check the fault is no longer present
All OK
End of test
Fault persists Seek the fault starting from another symptom
Check and, if required, replace CODE ECU
PROCEDURE OP. 5580E12

Parts & tools for this job For 1998 Fiat Seicento

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.