Diagnosis table K52
- Make
- Fiat
- Model
- Seicento Factory Service Manual
- Year
- 1998–2010
- Section
- On-board instruments › Diagnosis table K52
DiagnosisDiagnosis table K52
Diagnosis table K52
Code fault warning light on
When the engine is started, the “code” warning light stays on for longer than 0.7 seconds (after running the ECU initial test, the warning light should turn off)
The “E.I. fault” warning light comes on and turns off correctly
If at the same time the “E.I. fault” warning light stays on, see table K51
If at the same time the “E.I. fault” warning light does not come on when the engine is started, see table K54
| Step | Validity | Operation to be performed | Test results | ||
|---|---|---|---|---|---|
| OK | Problems found | Intervention | |||
| 1 | CHECK WITH DIAGNOSTIC TOOL Connect diagnostic tool (Examiner or other tools) to the diagnostic socket. Check: - no errors in the CODE ECU |
All OK Go to Step 2 |
Failed dialogue with the ECU | Restore connection between CODE ECU and diagnostic socket (Wiring diagram E7010 "CODE") |
|
| Error detected in ECU | Continue as shown by the diagnostic tool | ||||
| 2 | CHECK CORRECT OPERATION Check the fault is no longer present |
All OK End of test |
Fault persists | Seek the fault starting from another symptom Check and, if required, replace CODE ECU PROCEDURE OP. 5580E12 |
|
Parts & tools for this job For 1998 Fiat Seicento
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLSocket setSearch: socket set metric
- BOOKHaynes manualSearch: Haynes manual Fiat Seicento
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.