6. Pour same quantity of refrigerant oil into oil
charger as collected during recovery. If the
following components have been removed, add
the following additional quantity of lubricating
oil:
l
Condenser = 30 cm
3
l
Desiccant bag = 30 cm
3
l
Evaporator = 20 cm
3
l
Pipe/hose = 10 cm
3
7. Fit lid to oil charger.
8. Connect yellow hose to refrigerant station.
9. Open valve on oil charger.
10. Move pointer on refrigerant gauge to mark
position of refrigerant drop.
11. Slowly open correct valve on refrigerant station
and allow vacuum to pull refrigerant into
system.
12. Close valve on refrigerant station when correct
amount of refrigerant has been drawn into air
conditioning system.
13. Turn Main switch to 'OFF'.
14. Close valves on connectors.
15. Disconnect high and low pressure connectors.