DESCRIPTION AND OPERATION

Diagnosis of electrical faults is continually monitored
by the ECM in both the upstream sensors and
downstream sensors (NAS only). The sensor signal is
checked against stored minimum and maximum
threshold values equating to short and open circuit
conditions.

If an HO

2

S sensor should fail, the following fault codes

will be generated by the ECM diagnostics, which can
be retrieved by Testbook:

P1129 - Front heated oxygen sensors
transposed

Upstream sensor LH bank - electrical (NAS only)

P0130 - Stoichiometric ratio outside operating
band

P0132 - Short circuit to battery supply

P0134 - Open circuit

Downstream sensor LH bank - electrical

P0136 - Stoichiometric ratio outside operating
band

P0137 - Short circuit to battery supply

P0138 - Short circuit to ground or chemical shift
down

P0140 - Open circuit

Upstream sensor RH bank - electrical (NAS only)

P0150 - Stoichiometric ratio outside operating
band

P0152 - Short circuit to battery supply

P0154 - Open circuit

Downstream sensor RH bank - electrical

P0156 - Stoichiometric ratio outside operating
band

P0157 - Short circuit to ground

P0158 - Short circuit to battery voltage

P0160 - Open circuit

Upstream sensors aged (NAS only)

P0133 - Upstream sensor aged - Period time too
short LH bank

P0133 - Upstream sensor aged - Period time too
long LH bank

P0153 - Upstream sensor aged - Period time too
short RH bank

P0153 - Upstream sensor aged - Period time too
long RH bank

P1170 - Upstream sensor aged - ATV adaption
too lean LH bank

P1170 - Upstream sensor aged - ATV adaption
too rich LH bank

P1173 - Upstream sensor aged - ATV adaption
too lean RH bank

P1173 - Upstream sensor aged - ATV adaption
too rich RH bank

Sensor Heater faults

P0135 - Upstream heater LH bank - Short circuit
(NAS only)

P0135 - Upstream heater LH bank - Open circuit
(NAS only)

P0141 - Downstream heater LH bank - Short
circuit

P0141 - Downstream heater LH bank - Open
circuit

P0155 - Upstream heater RH bank - Short circuit
(NAS only)

P0155 - Upstream heater RH bank - Open circuit
(NAS only)

P0161 - Downstream heater LH bank - Short
circuit

P0161 - Downstream heater LH bank - Open
circuit

COMPONENT DESCRIPTIONS - from 99MY|Page 492 > < COMPONENT DESCRIPTIONS - from 99MY|Page 490