landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

COMPONENT DESCRIPTIONS - from 99MY|Page 492 > < COMPONENT DESCRIPTIONS - from 99MY|Page 490
Page 390
background image

LAND ROVER V8

55

DESCRIPTION AND OPERATION

Diagnosis of electrical faults is continually monitored
by the ECM in both the upstream sensors and
downstream sensors (NAS only). The sensor signal is
checked against stored minimum and maximum
threshold values equating to short and open circuit
conditions.

If an HO

2

S sensor should fail, the following fault codes

will be generated by the ECM diagnostics, which can
be retrieved by Testbook:

•

P1129 - Front heated oxygen sensors
transposed

Upstream sensor LH bank - electrical (NAS only)

•

P0130 - Stoichiometric ratio outside operating
band

•

P0132 - Short circuit to battery supply

•

P0134 - Open circuit

Downstream sensor LH bank - electrical

•

P0136 - Stoichiometric ratio outside operating
band

•

P0137 - Short circuit to battery supply

•

P0138 - Short circuit to ground or chemical shift
down

•

P0140 - Open circuit

Upstream sensor RH bank - electrical (NAS only)

•

P0150 - Stoichiometric ratio outside operating
band

•

P0152 - Short circuit to battery supply

•

P0154 - Open circuit

Downstream sensor RH bank - electrical

•

P0156 - Stoichiometric ratio outside operating
band

•

P0157 - Short circuit to ground

•

P0158 - Short circuit to battery voltage

•

P0160 - Open circuit

Upstream sensors aged (NAS only)

•

P0133 - Upstream sensor aged - Period time too
short LH bank

•

P0133 - Upstream sensor aged - Period time too
long LH bank

•

P0153 - Upstream sensor aged - Period time too
short RH bank

•

P0153 - Upstream sensor aged - Period time too
long RH bank

•

P1170 - Upstream sensor aged - ATV adaption
too lean LH bank

•

P1170 - Upstream sensor aged - ATV adaption
too rich LH bank

•

P1173 - Upstream sensor aged - ATV adaption
too lean RH bank

•

P1173 - Upstream sensor aged - ATV adaption
too rich RH bank

Sensor Heater faults

•

P0135 - Upstream heater LH bank - Short circuit
(NAS only)

•

P0135 - Upstream heater LH bank - Open circuit
(NAS only)

•

P0141 - Downstream heater LH bank - Short
circuit

•

P0141 - Downstream heater LH bank - Open
circuit

•

P0155 - Upstream heater RH bank - Short circuit
(NAS only)

•

P0155 - Upstream heater RH bank - Open circuit
(NAS only)

•

P0161 - Downstream heater LH bank - Short
circuit

•

P0161 - Downstream heater LH bank - Open
circuit

COMPONENT DESCRIPTIONS - from 99MY|Page 492 > < COMPONENT DESCRIPTIONS - from 99MY|Page 490