landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

HEATING AND VENTILATION FAULTS|Page 1377 > < HEATING AND VENTILATION FAULTS|Page 1375
Page 1128
background image

HEATING AND VENTILATION

3

FAULT DIAGNOSIS

Symptom - Heater Emits Ambient Air Only

POSSIBLE CAUSE

REMEDY

1. Air inlet housing vent flap

locked in ’open’ position due to
inoperative servo motor.

1. Renew servo motor.

2. Blown heating and ventilation

system fuse.

2. Check and renew fuses 8 or 17.

Symptom - No Boosted Air Supply To Heater Distribution Unit.

POSSIBLE CAUSE

REMEDY

1. Blower motor(s) inoperative.

1. Renew blower motor(s).

2. Blown motor fuse.

2. Check and renew fuses 42 or 43.

3. Loose electrical connections.

3. Check and tighten all relevant connections.

Symptom - Individual Heating and Ventilation Function/s Inoperative When Switch Control/s Are Used.

POSSIBLE CAUSE

REMEDY

1. Switch function faulty.

1. Renew switch control panel.

2. Switch control panel ECU

faulty.

2. Check and renew fuse 8 or fit new control panel.

Symptom - Heating and Ventilation System Inoperative.

POSSIBLE CAUSE

REMEDY

1. Blown heating and ventilation

system fuse.

1. Check and renew fuses 8 or 17.

2. Switch control panel ECU

faulty.

2. Check and renew fuse 8 or fit new control panel.

HEATING AND VENTILATION FAULTS|Page 1377 > < HEATING AND VENTILATION FAULTS|Page 1375