landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

AIR CONDITIONING FAULTS|Page 1421 > < OPERATION|Page 1418
Page 1168
background image

AIR CONDITIONING

1

FAULT DIAGNOSIS

AIR CONDITIONING FAULTS

This section covers mechanical and possible fuse
faults that could occur in the air conditioning system.
Visual checks of components within the system and
relevant fuses should be carried out before
undertaking detailed fault diagnosis procedures on
TestBook .

For details of possible faults to vent flap servo motors
that are common to heating, ventilation and air
conditioning systems.

See HEATING AND

VENTILATION, Fault diagnosis.

Symptom - Condenser Fan Motor Inoperative or Slow Running.

POSSIBLE CAUSE

REMEDY

1. Blown fuse.

1. Check and renew fuse 34.

2. Loose electrical connections.

2. Check and tighten all relevant connections.

3. Worn internal motor

components.

3. Renew fan motor.

Symptom - Condenser Fan Motor and/or Condenser Vibration.

POSSIBLE CAUSE

REMEDY

1. Fan motor and/or blades out of

alignment.

1. Check for visual damage.

2. Fan motor/s out of balance.

2. Balance fan motors.

3. Build up of debris on fan

blades.

3. Clean blades with a suitable non-inflammable cleaner.

4. Excessive wear of fan motor

bearings.

4. Renew condenser fan and motor assembly.

5. Condenser unit not mounted

securely.

5. Secure as necessary.

AIR CONDITIONING FAULTS|Page 1421 > < OPERATION|Page 1418