Sunshade Illumination Malfunction
Diagnostic Instructions
Diagnostic Fault Information
Circuit
|
Short to Ground
|
Open/High Resistance
|
Short to Voltage
|
Signal Performance
|
Sunshade Lamps B+
|
1, 2, 3
|
2
|
-
|
-
|
Sunshade Lamps Ground
|
-
|
2
|
1, 2, 3
|
-
|
1. Reading Lamps Always OFF
2. Sunshade Lamps Always OFF
3. Instrument Panel Compartment Lamp Always OFF
|
|
|
Circuit/System Description
The body control module (BCM) supplies the dome/reading lamps,
sunshade and instrument panel compartment lamp with battery
voltage. When switching on the following components the concerning
lamps will illuminate:
• |
Dome/reading lamps -
row |
• |
Instrument Panel compartment
lamp |
Reference Information
Schematic Reference
Interior Lights Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Interior Lighting Systems Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
Ignition ON, observe the lamp of the sunshade - left
front/sunshade - right front while opening and closing. The lamp
should illuminate when opened.
Circuit/System Testing
Sunshade Light Circuit Malfunction
1. |
Ignition OFF, disconnect the
harness connector at the appropriate sunshade. |
2. |
Disconnect the negative
terminal of the C1 Battery. |
3. |
Test for less than 5 Ω
between the ground circuit terminal B and ground. |
⇒ |
If greater than the specified range, test the
ground circuit for an open/high resistance. |
4. |
Reconnect the negative
terminal to the C1 Battery. |
5. |
Ignition ON, test for greater
than 11 V between the circuit terminal A and the ground circuit
terminal B. |
⇒ |
If less than the specified range, test the 12 V
circuit for a short to ground or an open/high resistance. If the
circuit tests normal, replace the K9 Body Control Module. |
6. |
If all circuits test normal,
test or replace the A3L Sunshade - Left or A3R Sunshade -
Right. |
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic
procedure.
|