01 General data and specifications02 Maintenance03 Diagnosis – checks04 Engine (1.6 and 2.0 Twin Spark)05 Clutch06 Gearbox (manual and Selespeed)07 Front axle08 Brakes, ABS and traction control09 Steering10 Suspension and wheels11 Heating, air conditioning and washers12 Electrical equipment13 Body14 Body panels and reinforcement15 Wiring diagrams16 Connectors and pin-outs17 Wiring harnesses18 Fault diagnosis19 Special tools
Alfa Romeo 147 Factory Service Manual (2000-2002)18 · Fault diagnosis
18 · Diagnostics

K10 Doors open check not working

Make
Alfa Romeo
Model
147 Factory Service Manual
Year
2000–2002
Section
Instruments › K10 Doors open check not working
Fault diagnosisK10 Doors open check not working

K10 Doors open check not working

When one of the doors is opened, this is not displayed by the special warning light/icon in the instrument panel. When the doors are opened, the interior lights work properly.

StepTest procedureResultAction
1CHECK WITH DIAGNOSTIC EQUIPMENT

Connect the Examiner to the diagnostic socket.

Verify:

  • that there are no faults in the Body Computer;
OK

Move onto step 2

There are faults in the Body Computer
  • Follow the instructions which come with the equipment

End of diagnosis

2CHECK WITH DIAGNOSTIC EQUIPMENT

Connect the Examiner to the diagnostic socket.

Verify:

  • that there are no faults in the instrument panel
OK

Move onto step 3

There are faults in the instrument panel
  • Follow the instructions which come with the equipment

End of diagnosis

3CHECK WITH DIAGNOSTIC EQUIPMENT

Connect the Examiner to the diagnostic socket.

Carry out the active diagnosis of the warning lights

OK

Move onto step 4

Warning light not working
  • Display/instrument panel defective Replace the instrument panel Op. 5560B11

End of diagnosis

4ELECTRICAL EQUIPMENT CHECK

Check connections between:

  • Body Computer and switches in locks
OK

Move onto step 5

Connections not correct

End of diagnosis

5SWITCH CHECK

Check the operation of the switches in the locks

OK

Move onto step 6

Lock with switch defective

End of diagnosis

6CORRECT OPERATION CHECK

Check that the fault is no longer present

OK

Incorrect selection of diagnostic procedure

Probable fault in Body Computer

Incorrect selection of diagnostic procedure

Parts & tools for this job For 2000 Alfa Romeo 147