Workshop Manuals Factory service & repair Alfa Romeo
01 General data and specifications02 Maintenance03 Diagnosis – checks04 Engine (1.6 and 2.0 Twin Spark)05 Clutch06 Gearbox (manual and Selespeed)07 Front axle08 Brakes, ABS and traction control09 Steering10 Suspension and wheels11 Heating, air conditioning and washers12 Electrical equipment13 Body14 Body panels and reinforcement15 Wiring diagrams16 Connectors and pin-outs17 Wiring harnesses18 Fault diagnosis19 Special tools
Alfa Romeo 147 Factory Service Manual (2000-2002)18 · Fault diagnosis
18 · Diagnostics

K15 Clock not working

Make
Alfa Romeo
Model
147 Factory Service Manual
Year
2000–2002
Section
Instruments › K15 Clock not working
Fault diagnosisK15 Clock not working

K15 Clock not working

With the ignition ON, the display does not display the time correctly or at all.

StepTest procedureResultAction
1INSTRUMENT PANEL FUNCTIONS CHECK

Verify:

  • That the display shows the correct time
  • That it is possible to adjust the time
  • That the clock moves forward
  • That the adjustment of the panel brightness has not been selected.
  • That the mode button has not been pressed
  • That no fault messages are displayed.
OK

Move onto step 2

The time displayed is not correct
  • Adjust the time

End of diagnosis

The time cannot be adjusted

Move onto step 2

The clock is stuck

End of diagnosis

The time is not displayed because there are priority messages or adjustments in progress.
  • Remove the cause of the priority messages

End of diagnosis

The display/time cannot be seen properly

Move onto step 2

2CHECK WITH DIAGNOSTIC EQUIPMENT

Connect the Examiner to the diagnostic socket.

Verify:

  • that there are no faults
OK

Move onto step 3

Errors present
  • Continue according to the instructions for the diagnostic equipment

End of diagnosis

3CHECK WITH DIAGNOSTIC EQUIPMENT

Connect the Examiner to the diagnostic socket.

Carry out the active diagnosis and check the condition of the display

OK

Move onto step 4

Display defective

End of diagnosis

4CHECK ELECTRICAL CIRCUIT

Verify:

OK

Move onto step 5

Connections defective; earth defective

End of diagnosis

5LEFT CONTROL PANEL CHECK

Check that the left control panel is working properly: Wiring diagram E4010 INSTRUMENT PANEL

OK

Move onto step 6

Left control panel defective

End of diagnosis

6CORRECT OPERATION CHECK

Check that the fault is no longer present

OK

Incorrect selection of diagnostic procedure

Fault persists

Incorrect selection of diagnostic procedure

Parts & tools for this job For 2000 Alfa Romeo 147

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.