Workshop Manuals Factory service & repair Alfa Romeo
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo Brera and Spider Factory Service Manual (2005-2010)23 · Fault diagnosis
23 · Diagnostics

Mode button not working

Make
Alfa Romeo
Model
Brera and Spider Factory Service Manual
Year
2005–2010
Section
Instrument panel › Mode button not working
Fault diagnosisMode button not working

MODE BUTTON NOT WORKING

The "Instrument Panel Node" receives information directly from the "Mode", "+" and "-" keys.

1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment and check, in Instrument Panel Node mode, that there are no errors and that the parameters are present.Move on to Step 61. Impossible to connect to the NQS1. Move on to Step 2
2. Presence of errors.2. Move on to Step 5
2ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the electricity supply to the Instrument Panel Node is correct.

See E2535 CONTROL LIGHTS

Move on to Step 3Fault in positive electrical supply and/or earthRenew and/or replace the defective component (in the case of a fuse, find out what caused it to blow).
3CHECK ELECTRICAL CONNECTIONSALL OKPROBLEMS ENCOUNTEREDACTION
Check the electrical wiring/connections of the instrument Panel Node and those between node and steering wheel stalk. Check, in particular, that each pin is correctly connected and inserted in its seat.Move on to Step 4Electrical wiring and/or connections not operating.Restore damaged wiring and/or electrical connections.
4CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Use an Examiner to check the possibility of connection to the Instrument Panel NodeMove on to Step 5Impossible to connect to the control unit.

Replace the instrument panel

Op. 5560B10 CONTROL PANEL - R+R

5ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the correct operation of the following components:

  • Wiring between node and steering wheel stalk
  • Control keys, see wiring diagram

See E4010 INSTRUMENT PANEL

Move on to Step 61. Wiring faulty1. Repair wiring.
2. Stalk controls malfunctioning.

2. Replace the steering column switch unit

Op. 5550A10 STALK UNIT ASSEMBLY - R+R

6CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosis