01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo Brera and Spider Factory Service Manual (2005-2010)23 · Fault diagnosis
23 · Diagnostics

Parking brake failure warning light on

Make
Alfa Romeo
Model
Brera and Spider Factory Service Manual
Year
2005–2010
Section
Instrument panel › Parking brake failure warning light on
Fault diagnosisParking brake failure warning light on

PARKING BRAKE FAILURE WARNING LIGHT ON

The handbrake/brake fluid warning light remains on with the handbrake released

0PRELIMINARY CHECKSAll OKProblems encounteredOperation

Check that the ABS warning light comes on and goes out during the initial test

Connect the diagnostic equipment and check the following at the CAN INFORMATION:

- No control units inactive

- No faulty control units

- No control units with faulty CAN line

Move on to Step 5The ABS warning light also remains on

Proceed as instructed in the

See table K062 ABS AND HANDBRAKE WARNING LIGHTS BOTH ON

Fault on CAN networkContinue following the instructions for the diagnostic equipment
Communication impossible with the Body ComputerMove on to Step 2
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the diagnostic equipment connected, check the plausibility of the brake fluid level parameter at the Body Computer NodeMove on to Step 4The parameter is not plausible

Replace body computer

Op. 5505A32 BODY COMPUTER - R.R

Impossible to connect to the Body Computer control unit.Move on to Step 2
2ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Body Computer Node is correctMove on to Step 3Fault in positive electrical supply and/or earthReplace the defective component (in the case of a fuse, find out what caused it to blow)
3CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the diagnostic equipment, check the possibility of connection to the Body Computer NodeMove on to Step 1Impossible to connect to the Body Computer control unit.

Replace Body Computer

Op. 5505A32 BODY COMPUTER - R.R

4CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsMove on to Step 5
5BRAKE FLUID LEVEL CHECKAll OKProblems encounteredOperation
Check that the brake fluid level is not lowMove on to Step 9Insufficient brake fluid levelMove on to Step 6
6BRAKE FLUID LEVEL TOP UPAll OKProblems encounteredOperation
Top up the brake fluid level and check that the warning light goes outEnd of diagnosisThe warning light does not go outMove on to Step 7
7CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the diagnostic equipment connected, check that there are no CAN faults at the BRAKE NODEMove on to Step 8Fault on C-CAN networkMove on to Step 14
8ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation

Disconnect the connector from the oil level sensor and check that it is working properly

See Test 3330AA INSUFFICIENT BRAKE FLUID LEVEL SENSOR CHECK

Move on to Step 9Brake fluid level sensor defectiveReplace the sensor
8ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation

Disconnect the connector from the oil level sensor and check that it is working properly

See Test 3330AA INSUFFICIENT BRAKE FLUID LEVEL SENSOR CHECK

Move on to Step 9Brake fluid level sensor defectiveReplace the sensor
9ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation

Check the continuity of the cable from the connector to the Body Computer

See E4010 INSTRUMENT PANEL

Move on to Step 10Lead broken

Repair the connection

See E4010 INSTRUMENT PANEL

10CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the diagnostic equipment and check the plausibility of the handbrake applied parameter at the Body Computer NodeMove on to Step 11The parameter is not plausibleMove on to Step 15
11CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the diagnostic equipment or keep it connected and check the operation of the brake fluid level warning light in active diagnosis at the Instrument Panel NodeMove on to Step 12The warning light does not flash

Replace instrument panel

Op. 5560B10 CONTROL PANEL - R+R

12ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correctMove on to Step 13Fault in positive electrical supply and/or earthReplace the defective component (in the case of a fuse, find out what caused it to blow)
13CHECK ELECTRICAL CONNECTIONSAll OKProblems encounteredOperation
Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connectedMove on to Step 14Electrical connections not operationalRenew the damaged electrical connections
14CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the diagnostic equipment connected, check the plausibility of the brake fluid level parameter at the Body Computer NodeMove on to Step 15The parameter is not plausible

Replace body computer

Op. 5505A32 BODY COMPUTER - R.R

15ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation
Check the insulation to earth of the wiring between the Handbrake lever switch and the Body ComputerMove on to Step 16Wiring not insulated

Restore wiring

See E4010 INSTRUMENT PANEL

16SWITCH CHECKAll OKProblems encounteredOperation
Check the condition of the switch on the handbrake leverMove on to Step 17Switch defective

Replace the switch

Op. 5550D18 HANDBRAKE ON WARNING LIGHT SWITCH - R+R

17ACTIVE DIAGNOSIS CHECKAll OKProblems encounteredOperation
With the Examiner in the Instrument Panel Node ambient check that the handbrake warning light is correctly activated in Active Diagnosis.Move on to Step 19The handbrake warning light does not flash

Replace the Instrument Panel

Op. 5560B10 CONTROL PANEL - R+R

Impossible to connect with the Instrument Panel NodeMove on to Step 18
18CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using an Examiner check, in Instrument Panel mode, that there are no errors and that the parameters are presentMove on to Step 19Presence of errorsContinue following the instructions on the diagnostic instrument
19CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner check, in the Body Computer ambient, that there are no errors and that the parameter specified variesMove on to Step 10Presence of errorsContinue by following the instructions on the diagnostic instrument
The parameters do not changeMove on to Step 10
20CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persists

Replace Body Computer

Op. 5505A32 BODY COMPUTER - R.R