RECHARGING WARNING LIGHT ON
After the engine has been started, the recharging warning light in the Instrument Panel Node remains on.
| 0 | PRELIMINARY CHECKS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
|---|---|---|---|---|
| Check that alternator terminal D+ delivers a voltage of at least 12V | Move on to Step 1 | The alternator does not deliver 12V | Move on to Step 11 | |
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Using an Examiner check, in Instrument Panel Node mode, that there are no errors. | Move on to Step 5 | 1. Impossible to connect to the Instrument Panel control unit. | 1. Move on to Step 2. | |
| 2. Presence of errors | 2. Continue following the instructions on the diagnostic instrument | |||
| 2 | ELECTRICAL POWER SUPPLY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the electricity supply to the Instrument Panel Node is correct. | Move on to Step 3 | Fault in positive electrical supply and/or earth | Replace defective component (in the case of a fuse, find out what caused it to blow). | |
| 3 | CHECK ELECTRICAL CONNECTIONS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected. | Move on to Step 4 | Electrical connections not operational | Renew the damaged electrical connections | |
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Use an Examiner to check the possibility of connection to the Instrument Panel Node | Move on to Step 5 | Impossible to connect to the Instrument Panel | Replace the Instrument Panel | |
| 5 | ACTIVE DIAGNOSIS CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| With the Examiner in Instrument Panel Node mode, check that the generator warning light is correctly activated in Active Diagnosis. | Move on to Step 6 | The alternator warning light is not activated | Replace the Instrument Panel | |
| 6 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Using an Examiner check, in Body Computer Node mode, that there are no errors. | Move on to Step 7 | 1. Impossible to connect to the Body Computer control unit. | 1. Move on to Step 7. | |
| 2. Presence of errors | 2. Continue following the instructions on the diagnostic instrument | |||
| 7 | ELECTRICAL POWER SUPPLY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the electricity supply to the Body Computer Node is correct. | Move on to Step 8 | Fault in positive electrical supply and/or earth | Replace defective component (in the case of a fuse, find out what caused it to blow). | |
| 8 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Use an Examiner to check the possibility of connection to the Body Computer Node | Move on to Step 9 | Impossible to connect to the Body Computer control unit. | Replace the Body Computer Node | |
| 9 | ELECTRICAL CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the continuity and insulation of the electrical circuit between the battery, starter motor and alternator | Move on to Step 10 | Connections faulty | Restore the correct connections and replace the faulty components if necessary. | |
| 10 | CHECK BATTERY CHARGE | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the battery charge | Move on to Step 11 | 1.Battery flat | 1. Recharge the battery | |
| 2.Battery flat and cannot be recharged | 2. Replace the battery | |||
| 11 | ALTERNATOR CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the alternator operates correctly | End of diagnosis | Alternator operating faults | Replace the alternator. |
‹ Prev Mode button not workingNext › One warning light activated by steering column switch unit not working
Parts & tools for this job For 2005 Alfa Romeo Brera
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLSocket setSearch: socket set metric
- BOOKHaynes manualSearch: Haynes manual Alfa Romeo Brera
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.