Detaching
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Servicing refrigerant circuit › Detaching
Air conditioningDetaching
Detaching
Drain the refrigerant circuit: Air conditioner with refrigerant R134a
Remove the brake master cylinder and brake servo. Brake systemRep. gr.47
Unfasten the refrigerant lines at the suspension strut dome by removing the bolt (A).

Screw out the hexagon socket-head bolt (A) (tightening torque 25 Nm).

Detach the refrigerant lines (B) and (C) from the evaporator and seal the open connections.
Note
- The cap of the replacement evaporator for example is a suitable means of sealing the open connections at the evaporator and the lines (to prevent the ingress of dirt and moisture).
Parts & tools for this job For 2002 Audi A8
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A8 2002 cabin filter
As an Amazon Associate we earn from qualifying purchases.