Removing and installing evaporator
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Servicing refrigerant circuit › Removing and installing evaporator
Removing and installing evaporator
Note
- As of Model Year 2008, a foam strip (3 x 3 mm, 65 mm long) (C) is gradually being introduced at the factory in the left and right tongue-and-groove joint between the bottom part of the housing (A) and the evaporator cover (B). The foam strips (C) are designed to prevent the ingress of moisture into the air conditioning unit by way of these joints.

Drain the refrigerant circuit: Air conditioner with refrigerant R134a
Remove the cover with air recirculation flap → Chapter.
Remove the fresh air blower V2Chapter.
Screw out the bolts (A).

Slacken off the bolt (C) and detach the corresponding holder for the coolant pipes.
Remove the bolt (B) with the holder for the coolant pipes.
Detach the cover for the evaporator (D).
Detach the refrigerant lines at the evaporator connection → Chapter.
Note
- On right-hand drive vehicles, remove the plenum chamber electronics box connector point if applicable.
Screw out the bolts (A).

Remove the connecting pipe (B).
Take out the evaporator.
Install in reverse order, paying attention to the following:
Prior to evaporator installation: Air conditioner with refrigerant R134a; replacing refrigerant circuit components
Before installing the evaporator, check the condensation drain openings (A) for dirt and clean if necessary.

Replace the O-rings (C) and (D) between the connecting pipe in the air conditioning unit (B) and the evaporator (E), version Electronic parts catalogue

Note
- Moisten the O-rings slightly with refrigerant oil before fitting → Chapter.
Fit the bolts (A) (tightening torque 5 Nm).
Note
- Pay attention to correct positioning of the O-rings (C) and (D) in the groove in the connecting pipes to the evaporator (E).
- Pay attention to correct positioning of the socket (B) to the air conditioning unit and at the connecting pipe for the evaporator (A).

- The evaporator removed contains refrigerant oil which has to be returned to the refrigerant circuit Air conditioner with refrigerant R134a
- As of Model Year 2008, a foam strip (3 x 3 mm, 65 mm long) (C) is gradually being introduced at the factory in the left and right tongue-and-groove joint between the bottom part of the housing (A) and the evaporator cover (B). The foam strips (C) are designed to prevent the ingress of moisture into the air conditioning unit by way of these joints.

- On fitting the evaporator cover (B), insert a foam strip (3 x 3 mm, 65 mm long) (C) in the left and right tongue-and-groove joint between the bottom part of the housing (A) and the evaporator cover (B) or seal these joints with adhesive sealant (e.g. silicone adhesive sealant D 176 001 A3) Electronic parts catalogue.
Re-install the other components removed.
Evacuate and refill the refrigerant circuit. Air conditioner with refrigerant R134a
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the notes on start-up of the air conditioner after charging Air conditioner with refrigerant R134a.
Parts & tools for this job For 2002 Audi A8
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A8 2002 cabin filter