Installing
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Servicing refrigerant circuit › Installing
Installing
Install in reverse order, paying attention to the following:
Prior to compressor installation Air conditioner with refrigerant R134a
- Tightening torques → Chapter and → Chapter.
- Replace the O-rings at the opened connections, version Electronic parts catalogue
Do not start the engine until the refrigerant circuit has been assembled
After fitting a new compressor or pouring in fresh refrigerant oil and before fitting the poly V-belt / drive shaft (e.g. after flushing the refrigerant circuit), crank the compressor 10 times by hand prior to initial start-up of the engine so as to prevent compressor damage.
If possible only start the engine with the refrigerant circuit filled
Note
- Different compressors depending on country version, production period and engine → Chapter and Electronic parts catalogue
- Moisten the O-rings slightly with refrigerant oil before fitting → Chapter.
- The compressor is always driven by the pulley/drive unit (there is no magnetic clutch).
- The compressor is equipped with an „internal oil circuit“ to prevent damage if the refrigerant circuit is empty. A prerequisite for this internal lubrication is that there is still a residual quantity of refrigerant oil in the compressor.
- The engine is not to be started unless the refrigerant circuit has been properly assembled. If, for example, the refrigerant lines have not been connected to the compressor, heat generation inside the compressor with the engine running may lead to the destruction of the compressor.
- The compressor removed contains an indeterminate amount of refrigerant oil. Attention is therefore to be paid to the notes on compressor replacement Air conditioner with refrigerant R134a
- The air conditioner compressor regulating valve N280 is not actuated if the refrigerant circuit is empty and the compressor runs at idle with the engine. However, as there is no refrigerant available, the refrigerant oil required for compressor lubrication is not conveyed. Compressor lubrication is maintained by way of an „internal oil circuit“ to prevent damage.
Should it be necessary to start the engine with the refrigerant circuit empty, heed the following so as not to damage the compressor → Chapter
Evacuate and charge the refrigerant circuit Air conditioner with refrigerant R134a.
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the notes on start-up of the air conditioner after charging Air conditioner with refrigerant R134a.
Parts & tools for this job For 2002 Audi A8
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A8 2002 cabin filter
As an Amazon Associate we earn from qualifying purchases.