Installing
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Servicing refrigerant circuit › Installing
Air conditioningInstalling
Installing
Install in reverse order, paying attention to the following:
Replace the O-rings (D) and (E); for version refer to Electronic parts catalogue
Tighten the bolts (B) to 25 Nm.
Note
- Use is not to be made of the O-rings from the caps of the replacement compressor connections.
- Moisten the O-rings slightly with refrigerant oil before fitting → Chapter.
- Following attachment of the refrigerant lines to the compressor (and after installing the compressor) check the routing of the lines. They must be inserted in the holders provided and not make contact with other components.
Evacuate and refill the refrigerant circuit Air conditioner with refrigerant R134a
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the notes on start-up of the air conditioner after charging Air conditioner with refrigerant R134a.