Servicing refrigerant circuit
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Servicing refrigerant circuit › Servicing refrigerant circuit
Air conditioningServicing refrigerant circuit
Servicing refrigerant circuit

- Air conditioner compressor regulating valve N280
Not to be removed
Checking actuation and operation → Chapter.NoteThe air conditioner compressor regulating valve N280 is actuated by the front operating and display unit, Climatronic control unit J255 and controls the compressor cooling output and the pressure on the low-pressure end of the refrigerant circuit. - Compressor
Detaching compressor from holder/re-attaching on vehicles with 6-cyl. engine, 8-cyl. MPI engine or 8-cyl. diesel engine (compressor drive via poly V-belt) → Chapter
Detaching compressor from holder/re-attaching on vehicles with 12-cyl. engine (compressor drive via poly V-belt) → Chapter
Detaching refrigerant line at compressor/attaching → Chapter
To protect the compressor, the engine is only to be started with the refrigerant circuit completely assembled.
Detaching poly V-belt Engine, mechanicsRep. gr.13
Removing and installing compressor (basic information) → Chapter
Removing and installing compressor on vehicles with 8-cyl. FSI engine (compressor drive via drive shaft) → Chapter
Removing and installing compressor on vehicles with 10-cyl. engine (compressor drive via drive shaft) → Chapter
The type of compressor differs depending on the engine (6, 8, 10 or 12-cyl. engine, diesel or petrol engine) Electronic parts catalogue
Following installation of a new compressor or after pouring in fresh refrigerant oil (e.g. after flushing the refrigerant circuit), give the compressor 10 turns by hand prior to initial start-up to prevent compressor damage.
Different refrigerant oil capacities apply to the refrigerant circuit depending on the type of compressor („6 SEU 14“, „7 SEU 16“ or „7 SEU 17“) Electronic parts catalogue and Air conditioner with refrigerant R134a - Pulley/drive unit for compressor
Replacing compressor pulley → Chapter
Removing and installing poly V-belt Engine, mechanicsRep. gr.13
Replacing compressor drive unit (vehicles with 8-cyl. FSI engine or 10-cyl. engine) → Chapter - Oil drain plug
A sealing ring is installed on the Denso compressor and is always to be replaced
Tightening torque: 30 Nm
The compressor must be removed before screwing out to drain off refrigerant oil. Crank the compressor by way of the pulley to accelerate discharge of the refrigerant oil - Pressure relief valve, 10 Nm
Not to be removed - Connection with valve
Use an adapter from the adapter set for service connections T10364 for example for removing and installing the valve insert with the refrigerant circuit drained.WARNINGThe refrigerant circuit must always be drained before removing the valve insert. - High-pressure sender G65
Removing and installing → Chapter
Checking signal → Chapter - Condenser
Detaching and re-attaching refrigerant lines → Chapter
Removing and installing condenser → Chapter - Cap
With seal
Always to be screwed on - Service connection/high-pressure end
Different versions (with primary sealing valve or Schrader valve) depending on the refrigerant line; distinguishing features Air conditioner with refrigerant R134a
Use an adapter from the adapter set for service connections T10364 for example for removing and installing the service connection or valve insert with the refrigerant circuit drained.
For service station for measuring pressure and draining and charging refrigerant circuit Air conditioner with refrigerant R134a
Depending on the engine version, certain components may have to be removed for connection of the service coupling.WARNINGThe refrigerant circuit must be drained before removing the service connections and valve inserts (the connection has no valve). - Union in refrigerant line
Replace O-ring, version Electronic parts catalogue
Tightening torque: 15 Nm - Restrictor
Fitted in union Item
O-ring: 7.5 mm / 1.5 mm
Replace restrictor with O-ring
Removing and installing → Chapter
Moisten O-ring slightly with refrigerant oil before fitting restrictor → Chapter - Evaporator
Replace O-rings, version Electronic parts catalogue
Removing and installing refrigerant line → Chapter
Removing and installing → Chapter - Service connection/low-pressure end
Different versions (with primary sealing valve or Schrader valve) depending on the refrigerant line; distinguishing features Air conditioner with refrigerant R134a
Use an adapter from the adapter set for service connections T10364 for example for removing and installing the service connection or valve insert with the refrigerant circuit drained.
For service station for measuring pressure and draining refrigerant circuit Air conditioner with refrigerant R134a
Depending on the engine version, certain components may have to be removed for connection of the service coupling.WARNINGThe refrigerant circuit must be drained before removing the service connections and valve inserts (the connection has no valve). - Cap
With seal
Always to be screwed on - Reservoir
Moisten O-rings slightly with refrigerant oil before fitting → Chapter
Replace O-rings, version Electronic parts catalogue
Tightening torque: Hexagon socket head bolt at block connection: 10 Nm
Removing and installing → Chapter
Parts & tools for this job For 2002 Audi A8
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A8 2002 cabin filter
As an Amazon Associate we earn from qualifying purchases.