Installing
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Servicing refrigerant circuit › Installing
Installing
Note
- Only fit restrictors of the same type. Restrictors of different colour have different bore diameters: Electronic parts catalogue
Check correct positioning of the O-ring (C) (7.5 mm; 1.5 mm) in the groove.
Before fitting, moisten the O-ring (of the restrictor and at the screw connection) with a small quantity of refrigerant oil → Chapter.
Ensure correct positioning of the restrictor (B) on installation (arrow on restrictor pointing towards evaporator).
Check positioning of the restrictor (snug fit in refrigerant line).
Replace the O-ring (D) (11.1 mm; 1.8 mm).

Take care not to strain the refrigerant lines on installation.
Tighten the screw connection (A) to 15 Nm.
Note
- Check the position of the refrigerant lines after tightening the screw connection (the refrigerant lines must not make contact with other components).
Evacuate and refill the refrigerant circuit. Air conditioner with refrigerant R134a
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the notes on start-up of the air conditioner after charging Air conditioner with refrigerant R134a.
Parts & tools for this job For 2002 Audi A8
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A8 2002 cabin filter
As an Amazon Associate we earn from qualifying purchases.