Workshop Manuals Factory service & repair Audi
01 Servicing 6-cylinder TDI engine, common rail (EA 897 Gen. I)02 6-cylinder TDI engine, 3.0 ltr. 4-valve common rail (EA 897 Gen. I)03 Fuel supply system, diesel engines04 6-cylinder direct injection engine with supercharger (3.0 ltr. 4-valve TFSI)05 Fuel supply system, petrol engines06 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)07 Technical data for engines08 Rear final drive 0D2, 0D3, 0DB09 8-speed automatic gearbox 0D510 8-speed automatic gearbox 0D711 Running gear: Specifications for testing the braking force (according to German legislation)12 Running gear: Trailer Operation Guide13 Running gear: Wheel/Tyre Guide14 Running gear, front-wheel drive and four-wheel drive15 Brake system16 Heating, air conditioning17 Heating and air conditioning: Auxiliary/supplementary heater18 Electrical: Communication19 Electrical system20 Electrical: Basic information on high-voltage vehicles21 General body repairs, interior22 General body repairs, exterior
Audi Q7 Mk2 (2015-2023)16 · Heating, air conditioning
16 · Heating & A/C

Cleaning the refrigerant circuit (routine “1”)

Make
Audi
Model
Q7 Mk2
Year
2015–2023
Section
Refrigerant circuit › Cleaning the refrigerant circuit (routine “1”)
Heating, air conditioningCleaning the refrigerant circuit (routine “1”)

Cleaning the refrigerant circuit (routine “1”)

Air conditioner with refrigerant R134a

Note

  • In this flushing process, the evaporator in the heater and air conditioning unit, the condenser with receiver, part of the valve block and the associated refrigerant lines are cleaned.

Requirements

  • The preparatory work for cleaning the refrigerant circuit has been carried outChapter“Preparatory work for cleaning the refrigerant circuit”.
  • The electrically operated valves installed in the refrigerant circuit are open or closed as specified for the flushing routine Vehicle diagnostic tester in “Guided Fault Finding” mode and Chapter“Preparatory work for cleaning the refrigerant circuit”

Cleaning refrigerant circuit

Close or open the shut-off valves installed in the flushing circuit as shown in the illustrations below.

Note

  • The illustrations below only apply to components that are directly affected by the flushing process, for all components not described Chapter“System overview - refrigerant circuit on vehicles with high-voltage system (Audi Q7 e-tron)”.
  • The colour of the lines in the illustrations below indicates which components are flushed (red lines) due to the different valve positions, which are only filled with refrigerant (green lines) and which are not affected (blue lines).

Components in the plenum chamber

A87-12221
Refrigerant expansion valve 1 N636 (closed via Basic settings routine)Adapter VAS 6338/44 (installed for expansion valve to evaporator in front heater and air conditioning unit)Shut-off valves VAS 6338/42 (installed in refrigerant line to expansion valve, opened manually)

Note

  • The N636(1) must be closed here, so that refrigerant cannot flow through the high-voltage battery heat exchanger.

Components in engine compartment

A87-12222
Adapter VAS 6338/12 (connected to refrigerant hose of air conditioner service station on high-pressure side)Shut-off valve 47-2 (installed in refrigerant line from internal heat exchanger, opened manually)Receiver on condenser (desiccant bag removed and re-sealed)Shut-off valve 47-1 (installed in refrigerant line from condenser, opened manually)Shut-off valve 47-1 (installed in refrigerant line from refrigerant receiver, closed manually)Shut-off valve 47-1 (installed in refrigerant line from valve block, closed manually)Refrigerant shut-off valve 4 N642 opened or closed via Basic settings routine (dependent on software of thermal management control unit J1024)Refrigerant shut-off valve 5 N643 (closed via Basic settings routine)Valve block (installed in area below left headlight)Refrigerant shut-off valve 3 N641 (opened via Basic settings routine)Refrigerant shut-off valve 2 N640 (closed via Basic settings routine)Adapter VAS 6338/3 (connected to refrigerant hose to flushing device)

Note

  • The N642(7) can be open or closed in this routine; since the N643(8) and the manual shut-off valve (6) are closed, this has no major influence on the flushing process.

Select “Flush air conditioner” routine on the connected air conditioner service station, and start routine.

Note

  • Note the instructions in the associated operating instructions.
  • For information on the flushing process, see Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Cleaning refrigerant circuit with refrigerant R134a)

Wait until the entire flushing process of the air conditioner service station has been performed and is complete.

Note

  • The end of the flushing process is displayed on the air conditioner service station.
  • The flushing process is complete when the air conditioner service station has extracted the refrigerant from the flushing circuit after the final flushing cycle.
  • If, due to an improperly closed valve, refrigerant reaches areas it is not actually intended to reach in this flushing routine (areas indicated by blue lines), it can take a very long time to extract all refrigerant from the flushing circuit. You can recognise a valve that does not close correctly e.g. by the fact that this valve cools down due to slowly evaporating refrigerant. The valve then constricts the flow. In this case, open all manually operated shut-off valves and, if necessary, switch on the air conditioner service station again, extract the remaining refrigerant from the flushing circuit and evacuate the circuit once more.

On completion of routine “1” initiate and run routine “2”Chapter.

Warning If the flushing process is interrupted or the cleaning process is not continued when this routine has ended, there is a risk of refrigerant escaping under pressure, frostbite on skin and other parts of the body.

  • Before removing flushing circuit components or detaching refrigerant lines, open all shut-off valves installed in the flushing circuit.
  • Initiate air conditioner basic settings via the thermal management control unit J1024 and use a routine stored there to open the various electrically operated valves Vehicle diagnostic testerin “Guided Fault Finding” mode.
  • Check the pressure in the flushing circuit using the air conditioner service station. If necessary, extract any remaining refrigerant and open the flushing circuit immediately afterwards.

Parts & tools for this job For 2015 Audi Q7

As an Amazon Associate we earn from qualifying purchases.