Removing and installing expansion valve (front)
- Make
- Audi
- Model
- Q7 Mk2
- Year
- 2015–2023
- Section
- Refrigerant circuit › Removing and installing expansion valve (front)
Removing and installing expansion valve (front)
Note
- After the air conditioner compressor is switched off, it might take a relatively long period on this vehicle before the pressure in the high-pressure side drops (the expansion valve is cold and the pressure in the low-pressure side increases rapidly after the compressor is switched off, the expansion valve is closed and the refrigerant can flow to the low-pressure side only slowly). If the air conditioner compressor is switched on, the pressure in the low-pressure side drops, the expansion valve is opened and the refrigerant can flow to the low-pressure side.
Vehicles with high-voltage system (Audi Q7 e-tron)
Initiate the basic settings of the air conditioner via the thermal management control unit J1024 and use a routine stored there “Extract, evacuate and charge refrigerant circuit” to open the electrically operated valves Vehicle diagnostic tester in “Guided Fault Finding” mode.
Note
- To drain, evacuate and fill the refrigerant circuit on vehicles with high-voltage system, the valves in the coolant circuit that are operated electrically must be open. Activate and open valves via a routine stored in the thermal management control unit J1024Vehicle diagnostic tester in “Guided Fault Finding” mode.
All vehicles
Switch off ignition.
Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Remove strut bar (D)Running gear, axles, steeringRep. gr.40Spring strut, axle strut (top); Removing and installing strut bar.

Detach bottom plenum chamber bulkhead (E) from vehicle and move to one side (do not remove) General body repairs, exteriorRep. gr.50Bulkhead; Exploded view - bulkhead.
Remove refrigerant lines (A, B) from the front expansion valve and place to one side (do not remove) Chapter“Detaching and re-attaching refrigerant lines from front expansion valve”.
Remove bolts (A).

Detach expansion valve (B) from refrigerant lines to evaporator.
Note
- Seal off open connections in the lines at the connection point using clean plugs, e.g. from engine bung set VAS 6122.

Install in reverse order of removal; note the following:
Make sure that the support ring (D) is correctly positioned and check the grommet in the back wall of the plenum chamber for damage and proper installation.
Clean connecting pipes (B) and (C) leading to the evaporator and check for damage.
Check retaining plate (D) on connecting pipes (B) and (C) for proper attachment to the connecting pipes leading to the evaporator.
Replace the O-rings (E) and (F); for correct version, refer to Electronic parts catalogue
Note
- Observe fitting instructions for O-rings Chapter“Refrigerant circuit seals”.
- Retaining plate (A) must be inserted in the mountings in connecting pipes (B) and (C).

- O-rings (D) and (E) are inserted in the grooves on connecting pipes (B) and (C)(arrows).
Lubricate O-rings lightly with refrigerant oil before installing Chapter“Refrigerant circuit seals”.
Check the connections on expansion valve (A) (to connecting pipes (C) and (E)) leading to the evaporator and check for damage.

Note
- There are different versions of the expansion valve (A) (identical housing but different characteristic control curve); therefore it is important to observe the correct assignment Electronic parts catalogue.
Renew O-rings (B) and (F); for correct version refer to Electronic parts catalogue.
Pay attention to correct positioning of the mounting plate (D) on the connecting pipes (C) and (E) to the evaporator.
Tighten bolts (G).
Tightening torque: 9 Nm.Attach the refrigerant line to the expansion valve Chapter“Detaching and re-attaching refrigerant lines from front expansion valve”.
Evacuating and charging refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Re-install remaining components (removed earlier).
Switch on ignition.
On vehicles with high-voltage system (Audi Q7 e-tron), initiate air conditioner basic settings via the thermal management control unit J1024and, using a routine stored there, enable the electrically operated valves“Stop routine: Filling/flushing refrigerant circuit”Vehicle diagnostic tester in “Guided Fault Finding” mode.
Interrogate the event memory of the front air conditioner operating and display unit E87 and erase any faults displayed Vehicle diagnostic tester in “Guided Fault Finding” mode.
Start up air conditioner after charging refrigerant circuit Chapter“Starting up air conditioner after charging refrigerant circuit”.
Note
- Also observe notes on starting up air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
Parts & tools for this job For 2015 Audi Q7
- PARTEngine gasket setSearch: Audi Q7 2015 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.