Workshop Manuals Factory service & repair Audi
01 Servicing 6-cylinder TDI engine, common rail (EA 897 Gen. I)02 6-cylinder TDI engine, 3.0 ltr. 4-valve common rail (EA 897 Gen. I)03 Fuel supply system, diesel engines04 6-cylinder direct injection engine with supercharger (3.0 ltr. 4-valve TFSI)05 Fuel supply system, petrol engines06 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)07 Technical data for engines08 Rear final drive 0D2, 0D3, 0DB09 8-speed automatic gearbox 0D510 8-speed automatic gearbox 0D711 Running gear: Specifications for testing the braking force (according to German legislation)12 Running gear: Trailer Operation Guide13 Running gear: Wheel/Tyre Guide14 Running gear, front-wheel drive and four-wheel drive15 Brake system16 Heating, air conditioning17 Heating and air conditioning: Auxiliary/supplementary heater18 Electrical: Communication19 Electrical system20 Electrical: Basic information on high-voltage vehicles21 General body repairs, interior22 General body repairs, exterior
Audi Q7 Mk2 (2015-2023)16 · Heating, air conditioning
16 · Heating & A/C

Separating refrigerant lines from condenser/connecting

Make
Audi
Model
Q7 Mk2
Year
2015–2023
Section
Refrigerant circuit › Separating refrigerant lines from condenser/connecting
Heating, air conditioningSeparating refrigerant lines from condenser/connecting

Separating refrigerant lines from condenser/connecting

Air conditioner with refrigerant R134a

Special tools and workshop equipment requiredAssembly tool T10118
W00-11303

Note

  • There are different condenser versions depending on the vehicle model. Electronic parts catalogue

Detaching

Vehicles with high-voltage system (Audi Q7 e-tron)

Initiate the basic settings of the air conditioner via the thermal management control unit J1024 and use a routine stored there “Extract, evacuate and charge refrigerant circuit” to open the electrically operated valves Vehicle diagnostic tester in “Guided Fault Finding” mode.

Note

  • To drain, evacuate and fill the refrigerant circuit on vehicles with high-voltage system, the valves in the coolant circuit that are operated electrically must be open. Activate and open valves via a routine stored in the thermal management control unit J1024Vehicle diagnostic tester in “Guided Fault Finding” mode.

All vehicles

Switch off ignition.

Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.

Remove front noise insulation General body repairs, exteriorRep. gr.66Noise insulation; Removing and installing noise insulation.

Vehicles with turbocharger on left: Remove closure plate for front bumper cover General body repairs, exteriorRep. gr.63Front bumper; Removing and installing attachments.

Remove left air intake grille General body repairs, exteriorRep. gr.63Front bumper; Removing and installing attachments.

Screw out the bolt (C).

A87-11919

Detach refrigerant lines (B, D) from the condenser (A).

Seal open connections at the lines and the connections at the condenser.

Note

  • Seal off open connections in the lines at the connection point using clean plugs, e.g. from engine bung set VAS 6122.

Installing

A87-11918

Attach in reverse order; note the following:

Clean the refrigerant line connections on the condenser (C) and the refrigerant lines (A, E) and check for damage.

Renew O-rings (D), for correct version, refer to Electronic parts catalogue.

Check the fitted pin (installed in the connection at the condenser or refrigerant line, not provided at all connections) for damage and proper attachment.

Note

  • Observe fitting instructions for O-rings Chapter“Refrigerant circuit seals”.
  • After attachment the refrigerant lines to the condenser, check the routing of the refrigerant lines; they must be inserted in the brackets provided and should not make contact with other components.

Lightly lubricate O-rings (J) and (K) with refrigerant oil before fitting Chapter“Refrigerant circuit seals”.

Pay attention to correct positioning of the O-rings on the refrigerant lines (A, E).

Insert refrigerant lines (A, E) in connections on condenser.

Insert and tighten bolt (F).

  • Tightening torque for bolt (F) with “M6” thread: 9 Nm

After attaching, check routing of refrigerant lines. They must be inserted tension-free in the brackets provided and should not make contact with other components.

Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.

Re-install remaining components (removed earlier).

Switch on ignition.

On vehicles with high-voltage system (Audi Q7 e-tron), initiate air conditioner basic settings via the thermal management control unit J1024and, using a routine stored there, enable the electrically operated valves“Stop routine: Filling/flushing refrigerant circuit”Vehicle diagnostic tester in “Guided Fault Finding” mode.

Interrogate the event memory of the front air conditioner operating and display unit E87 and erase any faults displayed Vehicle diagnostic tester in “Guided Fault Finding” mode.

Start up air conditioner after charging refrigerant circuit Chapter“Starting up air conditioner after charging refrigerant circuit”.

Note

  • Also observe notes on starting up air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.

Parts & tools for this job For 2015 Audi Q7