Cleaning the refrigerant circuit (routine “4”)
- Make
- Audi
- Model
- Q7 Mk2
- Year
- 2015–2023
- Section
- Refrigerant circuit › Cleaning the refrigerant circuit (routine “4”)
Cleaning the refrigerant circuit (routine “4”)
Note
- In this flushing process, part of the valve block and the associated refrigerant lines are cleaned.
- The preparatory work for cleaning the refrigerant circuit has been carried outChapter“Preparatory work for cleaning the refrigerant circuit”.
- Flushing routine “3” has been successfully performed and completed → Chapter.
Initiate air conditioner basic settings via the thermal management control unit J1024 and use a routine stored there to open or close the electrically operated valves for the fourth flushing process (flushing routine “4”), see illustrations below and Vehicle diagnostic tester in “Guided Fault Finding” mode.
Note
- If the various electrically operated valves in the valve block ( N640, N641 N642 and N643) are not open or closed as specified, it is not possible to clean all the components installed in the refrigerant circuit. The same applies to the electrically operated valve N636 installed in the plenum chamber.
- If the various manual shut-off valves installed are not in the correct position during flushing, it is not possible to clean all the components installed in the refrigerant circuit.
- If one of the valves in the refrigerant circuit does not open or close correctly, the flushing process and subsequent evacuation of the refrigerant circuit may take considerably longer or, depending on the flowrate of the valve in question, may not be possible in the intended manner.
Close or open the shut-off valves installed in the flushing circuit as shown in the illustrations below.
Note
- The illustrations below only apply to components that are directly affected by the flushing process, for all components not described Chapter“System overview - refrigerant circuit on vehicles with high-voltage system (Audi Q7 e-tron)”.
- The colour of the lines in the illustrations below indicates which components are flushed (red lines) due to the different valve positions, which are only filled with refrigerant (green lines) and which are not affected (blue lines).
Components in the plenum chamber

Note
- Shut-off valve (3) could also be open here; however, it is closed in order to better localise a fault in the event of malfunction.
Components in engine compartment

Select “Flush air conditioner” routine on the connected air conditioner service station, and start routine.
Note
- Note the instructions in the associated operating instructions.
- For information on the flushing process, see Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Cleaning refrigerant circuit with refrigerant R134a)
Wait until the entire flushing process of the air conditioner service station has been performed and is complete.
Note
- The end of the flushing process is displayed on the air conditioner service station.
- The flushing process is complete when the air conditioner service station has extracted the refrigerant from the flushing circuit after the final flushing cycle.
- If, due to an improperly closed valve, refrigerant reaches areas it is not actually intended to reach in this flushing routine (areas indicated by blue lines), it can take a very long time to extract all refrigerant from the flushing circuit. You can recognise a valve that does not close correctly e.g. by the fact that this valve cools down due to slowly evaporating refrigerant. The valve then constricts the flow. In this case, open all manually operated shut-off valves and, if necessary, switch on the air conditioner service station again, extract the remaining refrigerant from the flushing circuit and evacuate the circuit once more.
Open all manually operated shut-off valves in the flushing circuit (see above)
Switch on ignition.
Initiate the basic settings of the air conditioner via the thermal management control unit J1024 and use a routine stored there “Extract, evacuate and charge refrigerant circuit” to open the electrically operated valves Vehicle diagnostic tester in “Guided Fault Finding” mode.
Check pressure in flushing circuit; only detach the refrigerant hoses from the two adapters (1, 12) if the pressure is less than or equal to ambient pressure.
Warning If the flushing process is interrupted there is a risk of refrigerant escaping under pressure, frostbite on skin and other parts of the body.
- Before removing flushing circuit components or detaching refrigerant lines, open all shut-off valves installed in the flushing circuit.
- Initiate air conditioner basic settings via the thermal management control unit J1024 and use a routine stored there to open the various electrically operated valves Vehicle diagnostic testerin “Guided Fault Finding” mode.
- Check the pressure in the flushing circuit using the air conditioner service station. If necessary, extract any remaining refrigerant and open the flushing circuit immediately afterwards.
Switch off air conditioner service station.
Note
- Ensure the correct quantity of refrigerant oil when assembling the refrigerant circuit. If the air conditioner compressor is replaced, make sure the replacement compressor has the correct quantity of refrigerant oil. If the air conditioner compressor is not replaced, you need to determine how much refrigerant oil is in the compressor, and fill the correct quantity into the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (flushing electrically driven air conditioner compressor) and Air conditioner with refrigerant R134aRep. gr.87Capacities for refrigerant R134a, refrigerant oil and approved refrigerant oils.
- These air conditioner compressors are available as replacement parts with different oil capacities; please observe the oil quantity in the compressor Air conditioner with refrigerant R134aRep. gr.87Capacities for refrigerant R134a, refrigerant oil and approved refrigerant oils and exact part number Electronic parts catalogue.
- There are different refrigerant oil capacities for the refrigerant circuit depending on the type of air conditioner compressor. The reason for the different oil quantities in the air conditioner compressor for an otherwise identical refrigerant circuit is the design of the actual compressor; please note the different oil quantities. Too much oil in the circuit results in higher pressures and reduced system cooling output. Too little oil may lead to lubrication problems in the air conditioner compressor Air conditioner with refrigerant R134aRep. gr.87Capacities for refrigerant R134a, refrigerant oil and approved refrigerant oils.
Assemble the refrigerant circuit.
Note
- After installing the electrically driven air conditioner compressor and then charging the refrigerant circuit, first start up the compressor by way of the “Compressor run-in” function of the basic setting routine. Otherwise, the air conditioner compressor may be damaged if refrigerant oil has accumulated in the compression chamber of the air conditioner compressor due to inappropriate storage prior to installation Vehicle diagnostic tester (“Guided Fault Finding” for air conditioner).
- An electrically driven air conditioner compressor may only be activated when the refrigerant circuit is charged. Running the air conditioner compressor with the refrigerant circuit empty could lead to compressor damage Vehicle diagnostic tester (“Guided Fault Finding” for air conditioner).
Initiate air conditioner basic settings via the thermal management control unit J1024 and use a routine stored there to open the electrically operated valves “Stop routine: Charging/flushing refrigerant circuit”Vehicle diagnostic tester in “Guided Fault Finding” mode.
Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Re-install remaining components removed in reverse order.
Warning DANGER!High voltage can cause fatal injury
Danger of severe or fatal injuries from electric shock.
- Get the high-voltage system started up by a “specialist high-voltage engineer”.
Putting the high-voltage system back into operation EngineRep. gr.93Putting the high-voltage system back into operation.
Finally, interrogate event memory of thermal management control unit J1024 and the front air conditioner operating and display unit E87, and erase displayed entries if necessary Vehicle diagnostic tester in “Guided Fault Finding” mode.
Start up electrical air conditioner compressor V470 via “Compressor run-in” function Vehicle diagnostic tester (“Guided Fault Finding” for air conditioner and battery regulation).
Start up air conditioner after charging refrigerant circuit → Chapter.
Note
- Also observe notes on starting up air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
Parts & tools for this job For 2015 Audi Q7
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi Q7 2015 cabin filter
As an Amazon Associate we earn from qualifying purchases.