01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Ducato Factory Service Manual (2002-2006)08 · Engine
08 · Engine

Lpg pump operation check

Make
Fiat
Model
Ducato Factory Service Manual
Year
2002–2006
Section
Gpl tank and pipes › Lpg pump operation check
EngineLpg pump operation check

LPG PUMP OPERATION CHECK

Check 1043AA

2.0 16V · GPL

The operation test involves carrying out an overall power uptake test for the following loads:+

  • LPG pump;
  • Solenoid on LPG cylinder

Proceed as follows:

  • With all loads deactivated, measure battery voltage and ensure that no-load voltage is at least 12.8 V. Otherwise charge the battery.
  • Turn the ignition key to the OFF position;
  • Fit an ammeter probe to the battery negative lead.
  • Disconnect the LPG pump current sensor from the connector
  • Connect the connector terminal connected to the current sensor V to the battery +12 V via a bridge with a 15 A fuse interposed.

Check that overall load uptake is:

  • approximately 4 A with the LPG tank empty;
  • approximately 6.5 A with the tank full of LPG.

Switching to LPG is inhibited if current uptake by the LPG pump does not exceed a threshold of4 A, corresponding to tank condition when not empty.