01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Grande Punto Factory Service Manual (2005-2012)22 · Fault diagnosis
22 · Diagnostics

Climate control recirculation (automatic mode) not working

Make
Fiat
Model
Grande Punto Factory Service Manual
Year
2005–2012
Section
Climate control › Climate control recirculation (automatic mode) not working
Fault diagnosisClimate control recirculation (automatic mode) not working

CLIMATE CONTROL RECIRCULATION (AUTOMATIC MODE) NOT WORKING

For vehicles with AQS sensors only, the recirculation is not closed automatically if there is pollution (CO, NO2 toxic gases only)

Test results
1CHECK ON CORRECT OPERATION OF CLIMATE CONTROL NODEAll OKProblems encounteredOperation

With the engine started up, set the climate control system control unit to the AUTO position, adjust the temperature knob to 22°C, set the fan speed to 8 bars, then press the recirculation button (check that the symbol appears on the display). Check that the air flow rate varies during the opening/closing of the flap. Also locate the grille in the engine compartment for the air intake casing and check the air intake when switching from recirculation to outside air intake

When the control unit is set to the FULL AUTO function and the outside temperature is below 3°C the air intake flap opens automatically to prevent the windscreen from misting up

Move on to Step 2

1. The recirculation symbol does not appear on the display

2. The recirculation symbol appears on the display (but the recirculation does not operate)

1. Move on to Step 4

2. Move on to Step 2

2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation

Connect the Examiner diagnostic equipment and check:

- that there are no errors at the air recirculation actuator;

- that there are no faults in the AQS sensor

Move on to Step 5

1. Errors in the recirculation actuator.

2. Errors in the AQS sensor

1. Move on to Step 3

2. Move on to Step 4

3CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation

Keeping the Examiner diagnostic equipment connected, check, through active diagnosis,

- that the air recirculation is working properly;

- that all the LEDs and graphic LCD symbols in the display come on

Move on to Step 5

1. Air recirculation actuator not working

2. The LED with the recirculation symbol does not light up

1. Move on to Step 4

2. Replace the climate control system control unit

Op. 5040D14 CONTROL UNIT WITH AUTOMATIC AIR CONDITIONING CONTROL PANEL - R.R.

4CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation

- that the recirculation flap is working properly in automatic mode by carrying out the "Pollution sensor test".

If the result is negative

See Test 5040DD CHECK ON POLLUTION SENSOR SIGNAL (AQS)

End of diagnosis

1. AQS sensor not working

2. Wiring faulty

1.Replace AQS sensor

2. Repair the wiring

5CHECK ELECTRICAL CONNECTIONSAll OKProblems encounteredOperation

Check whether the electrical wiring connections are loose.

Remove the control unit from the panel mount, disconnect the wiring connector from the control unit and check visually for any damage to the connector and reconnect correctly to check for false contacts.

Remove the oddments pocket and disconnect the connector, inspecting visually for any damage to it and reconnect the electrical connector to the actuator

Move on to Step 6Electrical wiring connections loose or damagedRestore the correct wiring connections
6CHECK ON CORRECT OPERATION OF RECIRCULATION ACTUATORAll OKProblems encounteredOperation

Then proceed as follows: with the engine running, switch on the recirculation air intake function manually with the fan at the maximum speed. If the actuator works and the flap is driven, check whether the air flow rate varies during the movement by feeling it. Deactivate the function by returning the actuator to its original condition. Identify the air intake casing grille on the vehicle and check the air intake in the shift from recirculation to outside air and the other way round by feeling with your hand. If the result of the check is positive, do not replace the actuator. If there are further doubts as to the operation of the actuator, it is possible to carry out the check following the instructions described below if the air intake casing is easily accessible.

See Test 5040DE SEQUENTIAL PROCEDURE FOR CHECKING RECIRCULATION ACTUATOR OPERATION

Move on to Step 7Incorrect operation of recirculation actuator

Replace the recirculation actuator

Op. 5040D75 AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R

7RECIRCULATION ACTUATOR FLAP CHECKAll OKProblems encounteredOperation
Visually inspect that the air recirculation actuator flap completes its travel without any hinderanceEnd of diagnosis

1. Flap travel incomplete

2. Flap damaged

3. Kinematic mechanism damaged

1.Free from air recirculation actuator flap from the impediment

2.Replace the flap

3.Repair kinematic mechanism