01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Grande Punto Factory Service Manual (2005-2012)22 · Fault diagnosis
22 · Diagnostics

Fan does not work at different speeds

Make
Fiat
Model
Grande Punto Factory Service Manual
Year
2005–2012
Section
Climate control › Fan does not work at different speeds
Fault diagnosisFan does not work at different speeds

FAN DOES NOT WORK AT DIFFERENT SPEEDS

Automatic air conditioning

The fan does not work when the speed control button is used.

Test results
1CHECK ON OPERATION OF FAN BY CLIMATE CONTROL SYSTEM CONTROL UNITAll OKProblems encounteredOperation

With the engine started, set the climate control system control unit to the AUTO position, adjust the temperature to 22 °C, place the recirculation at the outside air intake and the distribution to the front position.

Adjust the fan button (+ side) gradually increasing the speed set and then decrease the speed using the button (- side), thereby checking the effect of the air flow rate variation.

End of diagnosisThe fan does not workMove on to Step 2
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation

Connect the diagnostic equipment and check:

- that there are no errors at the passenger compartment fan (motor + speed governor)

- that there are no errors linked to the fan (short circuit errors).

Move on to Step 4

1. Error at the passenger compartment fan

2. Short circuit error

3. Fan operating module error

1. Move on to Step 4

2. Move on to Step 3

3. Move on to Step 4

3CHECK ELECTRICAL CONNECTIONSAll OKProblems encounteredOperation
With the engine switched off, remove the control unit from the dashboard support and disconnect the connector visually inspecting for any damage at the connector contacts and reconnect it correctly to for check for any false contacts.Move on to Step 4Electrical connections loose or damaged

Restore the loose or damaged electrical connections

See E6020 AIR CONDITIONING

4CHECK ON ELECTRICAL CONNECTIONS AND FAN OPERATIONAll OKProblems encounteredOperation

Check whether the electrical wiring connections are loose:

Disconnect/reconnect the connection to the engine mounting.

Disconnect the connector and connect to a feeder (12V DC).

In these conditions the motor should turn at the maximum speed indicating that the operating moduel (speed governor) is not working

End of diagnosis

1. Electrical connections loose

2. The fan does not work

3. The operating module (speed governor) is not working

1. Renew the correct connections

See E6020 AIR CONDITIONING

2. Replace the fan

Op. 5040C30 AIR CONDITIONING FAN - R.R.

3. Replace the fan operating module

Op. 5040C44 FAN MOTOR ELECTRONIC VARIATOR - R+R

Manual air conditioning

The fan does not work when the speed control selector is used.

Test results
1CHECK ON CORRECT OPERATION OF SWITCH AT MAXIMUM SPEEDAll OKProblems encounteredOperation

Check for loose electrical wiring connections, disconnect visually inspecting for any damage to the connector contacts.

Reconnect the connection to the resistor.

Check that the fan is working at the maximum speed: if it only works at the maximum speed, the resistor is broken.

Move on to Step 2

1. Electrical connections loose or damaged

2. Ceramic resistor with T.F. blown

3. The fan only works at the maximum speed

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2. Replace the ceramic resistor

Op. 5040C48 A/C FAN MOTOR RESISTOR - R+R

3. Replace the ceramic resistor

Op. 5040C48 A/C FAN MOTOR RESISTOR - R+R

2CHECK ON CORRECT OPERATION OF FANAll OKProblems encounteredOperation

Check whether the electrical wiring connections are loose

See E6020 AIR CONDITIONING

Disconnect, visually inspecting for any damage to the connector contacts.

Reconnect the connection to the engine mounting.

Check that it turns at all speeds using the switch

Move on to Step 3

1. Electrical connections loose or damaged

2. Fan not working

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2. Replace the fan

Op. 5040C30 AIR CONDITIONING FAN - R.R.

3CHECK ON CORRECT OPERATION OF SWTICH AT THE CLIMATE CONTROL SYSTEM CONTROL UNITAll OKProblems encounteredOperation

Check for loose electrical wiring connections, disconnect visually inspecting for any damage to the connector contacts.

Reconnect the connection to the selector at the climate control system control unit

End of diagnosis

1. Electrical connections loose or damaged

2. Switch damaged or not working

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2. Replace the switch

Op. 5040D10 AIR CONDITIONER CONTROLS SUPPORT - R+R OR REPLACE