Fault diagnosisClimate control too cold
CLIMATE CONTROL TOO COLD
The control button operates the passenger compartment air fan normally, but the temperature of the air is not correct.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check that the evaporator air filter is not clogged | End of diagnosis | Evaporator air filter blocked | Replace evaporator filter | |
| 1 | CHECKING SYSTEM PRESSURE | All OK | Problems met | Operation |
| Connect the climate control system to the repressurizing equipment and check the system pressure See Test 5040A CHECK ON OPERATION OF AIR CONDITIONING SYSTEM (TEMPERATURE) | Continue to Step 2 | System pressure incorrect. | Restore correct system pressure. | |
| Coolant pressure too low or too high | Restore the correct coolant level | |||
| 2 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Connect the examiner and check for errors at the air mixing motors | Continue to Step 4 | Air mixing motor error | Continue to Step 3 | |
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check the continuity/insulation of the electrical connection for the air mixing motors | Continue to Step 7 | Electrical conection broken or not insulated. | Restore electrical connection continuity/insulation. | |
| 4 | CHECKING PIPES AND FILTER | All OK | Problems met | Operation |
| Check high and low pressure pipes and air conditioning system filter are not blocked. | Continue to Step 5 | Pipes from compressor to condenser blocked. | Change the pipe from compressor to condenser | |
| Pipe from filter to expansion valve blocked. | Change the pipe from filter to expansion valve | |||
| Drier filter blocked and/or damaged. | Replace the filter Op. 5040A48 | |||
| 5 | CONDENSER CHECK | All OK | Problems met | Operation |
| Check that the condenser is not blocked. | Continue to Step 6 | Condenser blocked | Replace the condenser Op. 5040A40 | |
| 6 | EXPANSION VALVE CHECK | All OK | Problems met | Operation |
| Check that the expansion valve is working properly | Continue to Step 8 | Expansion valve blocked shut. | Replace the expansion valve Op. 5040B30 | |
| 7 | CHECKING CORRECT OPERATION USING TESTER | All OK | Problems met | Operation |
| Check that the errors at the air mixing motors do not persist (after the self-learning procedure) | End of diagnosis | Air mixing motor error | Replace the mixed air motor | |
| 8 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the climate control system node | |