When the required temperature is set on the passenger side, no air flow is felt at the required temperature
| Results of the tests | ||||
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
| Connect the Examiner, check for errors on the passenger side air mixing motor | Continue to Step 2 | Air mixer motor error | Continue to Step 3 | |
| 2 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Keep the Examiner connected and check air recirculation motor operation by means of active diagnosis | Continue to Step 7 | Air mixing motor does not work | Continue to Step 3 | |
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of the electrical connection between climate control Node and passenger side air mixing motor See E6020 AIR CONDITIONING | Continue to Step 4 | Electrical conection broken or not insulated. | Restore continuity/insulation of electrical connection See E6020 AIR CONDITIONING | |
| 4 | CHECKING AIR MIXING MOTOR OPERATION | All OK | Problems met | Operation |
| Check for a control signal from the climate control node. See E6020 AIR CONDITIONING | Continue to Step 5 | No signal | Continue to Step 7 | |
| 5 | CHECK AIR MIXER MOTOR FLAP | All OK | Problems met | Operation |
| Check that the air mixing motor flap moves through its travel without sticking. | Continue to Step 6 | Flap blocked or damaged | Release the air recirculation motor flap from its block or replace the flap if damaged. | |
| 6 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present. | End of diagnosis | Fault persists | Change the passenger side air mixer motor. Op. 5040D86 | |
| 7 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the climate control system node | |